Chapter 5
5-8
F-5-14
5.3.3.2 Scanning Lamp
0015-4397
iR5065 / iR 5055 / iR5075 / / /
The machine's scanning lamp is a xenon lamp consisting of a tube in which xenon gas is sealed. On the inner side of the glass tube are 2 electrodes running parallel
to the tube axis, while the inner side is coated with fluorescent material. When high-frequency high voltage is applied to the electrodes, the gas inside the tube starts
to discharge, thus illuminating the fluorescent material.
F-5-15
5.3.3.3 Controlling the Activation
0015-4399
iR5065 / iR 5055 / iR5075 / / /
The machine turns on or off the scanning lamp using the drive signal (XE_ON) from the CPU on the reader controller PCB. In response to the signal, the inverter
PCB generates high-frequency high voltage in the activation control circuit using the drive voltage (+24 V) supplied by the reader controller PCB, thus turning on
the xenon lamp.
5.3.4 Detecting the Size of Originals
5.3.4.1 Overview
0015-4401
iR5065 / iR 5055 / iR5075 / / /
The machine identifies the size of an original with reference to the combination of measurements taken of the light reflected at specific points of the CCD and the
output of a reflection type sensor. It takes measurements at 2 points for individual sizes to ensure correct identification even in the event that the original is displaced
while the ADF is being closed.
- for main scanning direction, by the CCD (for AB, 8 points; for inch-configuration, 6 points)
- for sub scanning direction, by a reflection type photosensor (for AB-configuration, 1 point; for inch-configuration, 1 point)
The machine identifies the size of an original as follows:
1) External Light (main scanning direction only)
While keeping the scanning lamp off, the machine measures the CCD level at individual points of measurement in main scanning direction.
2) Sensor Output Level
The machine turns on the scanning lamp, and measures the CCD level at individual points of measurement in main scanning direction. Also, the machine turns
on the LED of the reflection type photosensor in sub scanning direction to measure the sensor output. It uses the combination of the measurement and the output
to identify the size of the original in question.
5.3.4.2 Points of Measurement Used for Original Size Identification
0015-4403
iR5065 / iR 5055 / iR5075 / / /
For main scanning direction, the machine moves the No. 1 mirror base to the point of CCD original detection to measure the CCD level at individual points of
measurement. For sub scanning direction, the machine uses the outputs of original sensors 1 and 3.
F-5-16
1. Checking the Presence/Absence of an Original at 2 Points (individual points of detection)
For main scanning direction, the machine identifies the presence/absence of an original with reference to the CCD output at 2 points (nearest).
Inverter PCB
scanning lamp
Activation
control
circuit
J601
J206
Reader controller PCB
LA1
CPU
GND
GND
GND
GND
XE-ON
24V
24V
XSYNC
24V
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Fluorescent
material
Electrode
Opening
Electrode
Electrode
Electrode
Glass tube
Point of original
detection 3
Point of original
detection 4
Point of original
detection 1
Print of original
detection 2
B5
B6
A5
A4
B5R
A4R
B4
A3
CCD original detection position
Point of original
detection 2
Point of original
detection 1
Point of original
detection 3
LTRR
STMT
LTR
LGL
279.4×431.8mm
(11"×17")
CCD original detection position
Original
sensor 3
AB-Configuration
Inch-configuration
STMTR
Original
sensor 1
Содержание imageRUNNER 5065 series
Страница 1: ...Feb 26 2007 Service Manual iR5075 5065 5055 Series ...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction ...
Страница 28: ......
Страница 30: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 98: ...Chapter 2 2 42 ...
Страница 99: ...Chapter 3 Basic Operation ...
Страница 100: ......
Страница 102: ......
Страница 108: ......
Страница 109: ...Chapter 4 Main Controller ...
Страница 110: ......
Страница 112: ......
Страница 129: ...Chapter 5 Original Exposure System ...
Страница 130: ......
Страница 162: ......
Страница 163: ...Chapter 6 Laser Exposure ...
Страница 164: ......
Страница 166: ......
Страница 172: ......
Страница 173: ...Chapter 7 Image Formation ...
Страница 174: ......
Страница 178: ......
Страница 210: ......
Страница 211: ...Chapter 8 Pickup Feeding System ...
Страница 212: ......
Страница 263: ...Chapter 9 Fixing System ...
Страница 264: ......
Страница 268: ......
Страница 307: ...Chapter 10 External and Controls ...
Страница 308: ......
Страница 312: ......
Страница 321: ...Chapter 10 10 9 F 10 8 ...
Страница 345: ...Chapter 11 MEAP ...
Страница 346: ......
Страница 348: ......
Страница 389: ...Chapter 12 RDS ...
Страница 390: ......
Страница 392: ......
Страница 399: ...Chapter 13 Maintenance and Inspection ...
Страница 400: ......
Страница 402: ......
Страница 411: ...Chapter 14 Standards and Adjustments ...
Страница 412: ......
Страница 440: ......
Страница 441: ...Chapter 15 Correcting Faulty Images ...
Страница 442: ......
Страница 444: ......
Страница 470: ......
Страница 471: ...Chapter 16 Self Diagnosis ...
Страница 472: ......
Страница 474: ......
Страница 493: ...Chapter 17 Service Mode ...
Страница 494: ......
Страница 496: ......
Страница 552: ......
Страница 553: ...Chapter 18 Upgrading ...
Страница 554: ......
Страница 556: ......
Страница 572: ...Chapter 18 18 16 F 18 29 2 Click Start F 18 30 3 When the session has ended click OK ...
Страница 587: ...Chapter 18 18 31 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Страница 589: ...Chapter 19 Service Tools ...
Страница 590: ......
Страница 591: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 List of Special Tools 19 1 19 1 2 List of Solvents Oils 19 1 ...
Страница 592: ......
Страница 595: ...Feb 26 2007 ...
Страница 596: ......