Error Code
Error Code Details
Ecode
Detail Code
Item
Description
E000
0001
Title
Fixing temperature abnormal rise
Description
The temperature detected by the main thermistor does not rise to
the specified value during startup control.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E001
0000
Title
Fixing unit temperature rise detection
Description
The reading of the main thermistor is 250 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E001
0001
Title
Fixing unit temperature rise detection
Description
The hardware circuit detects overheating of the main or sub ther-
mistor for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Replace the DC Controller PCB (PCB4).
E001
0002
Title
Fixing unit temperature rise detection
Description
The reading of the sub thermistor is 295 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E002
0000
Title
Fixing unit temperature insufficient rise
Description
1.The reading of the main thermistor is less than 115 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E003
0000
Title
Low fixing temperature detection after standby
Description
The reading of the main thermistor is less than 140 deg C contin-
uously for 400 msec or more.
7. Error/Jam/Alarm
201
Содержание imageRUNNER 2520 Series
Страница 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 16: ...Product Overview 1 Product Lineup 7 Features 10 Specifications 11 Name of Parts 15 Operation 18 ...
Страница 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Страница 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Страница 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Страница 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Страница 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Страница 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Страница 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Страница 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Страница 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Страница 223: ...Jam Code Main Unit 550 sheet 1st cassette model S1 S5 S7 S19 S12 S42 S40 7 Error Jam Alarm 213 ...
Страница 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Страница 314: ...Example of report display 8 Service Mode 304 ...
Страница 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...