4. Power/Electrical
Requirements
The imagePRESS C7000VP requires a NEMA L21-30 receptacle for the main unit
and proper operation.
4.1 Power Requirements for the Main Unit and Optional Accessories
Part or
Accessory
NEMA L21-30 Receptacle
Power Supply Cord/Plug
Specifications
Power Supply
Length of
Power Cord
Main Unit
3 Phase 208 V/30 A outlet
NEMA L21-30
9’ 8” (3 m)
POD Deck-A1
*1
1-208 V/6 A outlet
(regardless of the number of
POD Decks connected)
NEMA 6-15
UL498, 2-pole, 3-wire,
grounding devices rated
250 V/15 A
6’ (1.8 m)
High Capacity
Stacker-C1
*2
1-115 V/7 A outlet
(regardless of the number of
stackers connected)
NEMA 5-15
6’ (1.8 m)
Saddle
Finisher-AB2
1-208 V/8 A outlet
NEMA 6-15
UL498, 2-pole, 3-wire,
grounding devices rated
250 V/15 A
6’ (1.8 m)
Finisher-AB1
1-208 V/8 A outlet
NEMA 6-15
UL498, 2-pole, 3-wire,
grounding devices rated
250 V/15 A
6’ (1.8 m)
imagePRESS
Server A2000
1-115 V/6 A outlet
NEMA 5-15
6’ (1.8 m)
imagePRESS
Server A3000
2-115 V/6 A outlets
NEMA 5-15
6’ (1.8 m)
*1 The Secondary POD Deck-A1 draws power from the POD Deck-A1.
*2 If you connect a second High Capacity Stacker-C1, the second stacker draws power from
the first stacker.
IMPORTANT
•
If the optional Advanced Controller Interface Kit is installed on the
imagePRESS Server A2000 (standard equipment on the imagePRESS
Server A3000), an additional 115 V/6 A (NEMA 5-15) is required.
•
We recommend an additional standard 115 V/15 A outlet for service tools,
such as a laptop or vacuum that may be attached.
•
Use only dedicated outlets for the main unit and each optional accessory.
Do not use extension cords.
Version 1 imagePRESS C7000VP Customer Expectations Document Page 13