Horizontal white streaks with 2mm intervals on a high density
green image
[Symptom]
In a usage under a low humidity environment, horizontal white streaks [a] with 2mm intervals may occur on a high density green
image
The arrow [b] indicates the direction of feeding.
[Cause]
Being affected by the influence of toner or ITB, the electric current may become uneven even if a constant primary transfer voltage
is applied.
If an electrical discharge phenomenon is generated on a part where has more current after the transfer, the electric charge amount
varies among the toner on the paper.
When the electric charge amount varies, the amount of toner that was once transferred to paper and to be attracted to the drum
(retransfer) at the next station changes, so that the toner amount on the paper becomes uneven and results in the above
mentioned symptom.
A low humidity environment is likely to have this symptom as the primary transfer voltage is large.
[Service work]
1) Have the customer log in from System Management Mode in user mode.
2) Go to Select Settings/Registration > Paper Settings > Paper Type Management Settings, select an appropriate paper type
from among the list, press "Duplicate" button and then "OK" button.
3) Enter any name as the duplicated paper type and press "OK" button.
5
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...