COPYRIGHT © 1998 CANON INC. FINISHER-C1/SADDLE FINISHER-C2 REV. 0 DEC. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
6-36
CHAPTER 6 TROUBLESHOOTING
14. E5F9 (faulty microswitch; detail code 03)
Step
Checks
Yes/No
Action
Cause
1
No
Switch actuator
Check the delivery door switch
actuator. Do the switch and the
sensor operate correctly?
Correct the mechanism.
2
No
Delivery switch (MS3S)
Check the delivery door switch. Is
the switch normal?
Replace the switch.
3
Yes
Delivery door open sensor
(PI3S)
Measure the voltage at J11-9 on
the saddle stitcher controller PCB
with the delivery door open. Is it
5 V?
The sensor is faulty. Replace the
sensor.
No
Replace the saddle stitcher
controller PCB.