7
7
7-24
7-24
Installation > Installation Procedure > Connecting with the Perfect Binder
Installation > Installation Procedure > Connecting with the Perfect Binder
8) Check the height between Finisher and the High Capacity Stacker.
CAUTION:
Height difference should be /- 2 mm.
Execute "Height Adjustment" if the difference is +/- 2 mm or more.
High Capacity Stacker
Finisher
9) Install the Rear Small Cover. (1 Screw)
10)
Install the Shunt Cable.
• 2 Screws (RS tightening; M4x10)
x2
F-7-65
F-7-66
Connecting with the Perfect Binder
NOTE:
Be sure the power of the host machine is turned OFF and the power plug is
disconnected from the outlet.
1) IInstall the Latch Receiver (Front) and Latch Receiver (Rear) in the left side of the Perfect
Binder.
• 4 Screws (RS tightening; M4x10)
CAUTION:
Confirm the engraved mark on each latch plate when attaching.
• Latch Receiver (Front) : F
• Latch Receiver (Rear) : R
R
F
Latch Receiver (Front)
Latch Receiver (Rear)
x4
F-7-67