5
5
5-11
5-11
Adjustments > Adjustment Method > Tray Width Adjustment
Adjustments > Adjustment Method > Tray Width Adjustment
Sensor Output Adjustment
CAUTION:
• When the sensor is replaced, be sure to clean the surface of prism before
adjustment.
• Make sure that there is no paper in DADF.
1) Execute the service mode items.
Lv.
FEEDER > FUNCTION >
1
SENS-INT
T-5-38
Tray Width Adjustment
Execute either [a. AB type adjustment] or [b. Inch type adjustment] in this adjustment.
a. AB type adjustment
1) Highlight the service mode item.
Lv.
FEEDER > FUNCTION >
1
TRY-A4
2) Set the slide guide to [A4/A3] display.
3) Press OK key to register the A4 width.
4) Highlight the service mode item.
Lv.
FEEDER > FUNCTION >
1
TRY- A5R
5) Set the slide guide to [A5R] display.
6) Press OK key to register the A5R width.
b. Inch type adjustment
1) Highlight the service mode item.
Lv.
FEEDER > FUNCTION >
1
TRY-LTR
2) Set the slide guide to [LTR/11 x 17] display.
3) Press OK key and register the letter width.
4) Highlight the service mode item.
Lv.
FEEDER > FUNCTION >
1
TRY- LTRR
5) Set the slide guide to [STMT/ LTRR/ LGL] display.
6) Press OK key and register the LTRR width.
T-5-39
T-5-40
T-5-41
T-5-42
Содержание F-1