Adjustments > Adjustment Method > Angle Restriction Release (Opening Angle at 90 deg)
Adjustments > Adjustment Method > Angle Restriction Release (Opening Angle at 90 deg)
Preparation or Creation of Test Chart
Prepare a test chart. If there is no test chart, create a test chart.
Create a test chart that has a 10 mm smaller rectangle from the edge of A4 or LTR paper.
10 mm
10 mm
10 mm
10 mm
Note:
Be sure to write a character or mark to identify the printed image direction.
F-5-5
Angle Restriction Release (Opening Angle at 90 deg)
Change the opening angle of DADF from 70 deg to 90 deg.
Note:
Increasing the opening angle of DADF makes some operation easier.
1) Open the rubber cover and remove the angle restriction plate.
• 2 screws
Rubber cover
Screw
Angle restriction plate
Rubber cover
CAUTION:
After adjustment, be sure to install the angle restriction plate.