5
5
5-5
5-5
Adjustments > Adjustment Method > Measurement during Reader Controller PCB Replacement and After RAM Clear
Adjustments > Adjustment Method > Measurement during Reader Controller PCB Replacement and After RAM Clear
Adjustment Method
Measurement during Reader Controller PCB
Replacement and After RAM Clear
CAUTION:
Before replacing Reader Controller PCB, be sure to make an output of the newest
P-PRINT.
(Lv.1) COPIER > FUNCTION > MISC-P > P-PRINT
1) Using SST, download the newest system software (R-CON).
2) Perform RAM clear.
Lv.
COPIER > FUNCTION > CLEAR >
1
R-CON
3) Turn the connecting equipment OFF/ON.
4) Perform the input or adjustment for MTF value.
4-1) Input the MTF value of P-PRINT outputted before replacement.
Lv.
COPIER > ADJUST > CCD >
1
MTF2-M1
MTF2-M7
MTF2-S1
MTF2-S7
MTF2-M2
MTF2-M8
MTF2-S2
MTF2-S8
MTF2-M3
MTF2-M9
MTF2-S3
MTF2-S9
MTF2-M4
MTF2-M10
MTF2-S4
MTF2-S10
MTF2-M5
MTF2-M11
MTF2-S5
MTF2-S11
MTF2-M6
MTF2-M12
MTF2-S6
MTF2-S12
4-2) Input the MTF value of P-PRINT outputted before replacement.
Lv.
COPIER > ADJUST > CCD >
1
MTF-M1
MTF-M7
MTF-S1
MTF-S7
MTF-M2
MTF-M8
MTF-S2
MTF-S8
MTF-M3
MTF-M9
MTF-S3
MTF-S9
MTF-M4
MTF-M10
MTF-S4
MTF-S10
MTF-M5
MTF-M11
MTF-S5
MTF-S11
MTF-M6
MTF-M12
MTF-S6
MTF-S12
T-5-3
T-5-4
T-5-5
4-3) Perform the MTF filter coefficient computation.
Lv.
COPIER > FUNCTION > CCD >
1
MTF-CLC
5) Input the value written the service label (the inside of PCB cover) (Total: 42 items).
Lv.
COPIER > ADJUST > ADJ-XY >
1
ADJ-X
ADJ-Y-DF
ADJ-X-MG
ADJY-DF2
ADJ-Y
STRD-POS
-
-
Lv.
COPIER > ADJUST > CCD >
1
W-PLT-X
DFTBK-R
DFCH2G2
DFCH-B10
W-PLT-Y
DFTBK-G
DFCH2G10
DFCH-G2
W-PLT-Z
DFTBK-B
DFCH2K2
DFCH-G10
SH-TRGT
DFTBK-BW
DFCH2K10
DFCH-K2
DFTAR-R
DFCH2R2
DFCH-R2
DFCH-K10
DFTAR-G
DFCH2R10
DFCH-R10
100-RG
DFTAR-B
DFCH2B2
DFCH-B2
100-GB
DFTAR-BW
DFCH2B10
-
-
2
100DF2RG
100DF2GB
-
-
Lv.
COPIER > ADJUST > PASCAL >
1
OFST-P-K
OFST-P-Y
OFST-P-M
OFST-P-C
Note:
When the value of the following item in the service label is negative, it may not be
possible to enter in the service mode screen.
(Lv.1) COPIER > ADJUST > ADJ-XY > STRD-POS
Only if the value cannot be entered, there is no need to enter “STRD-POS”. However, it
is necessary to perform the stream reading adjustment.
"Stream Reading Adjustment"(page 5-18).
6) Perform computation for front & back linearity matching.
Lv.
COPIER > FUNCTION > CCD >
1
DF-LNR
7) Input the value written in the service label (inside PCB cover).
Lv.
FEEDER > ADJUST >
1
DOCST
LA-SPEED
DOCST2
LA-SPD2
T-5-6
T-5-7
T-5-8
T-5-9
Содержание F-1
Страница 14: ...2 2 Technology Technology Basic configuration Controls Service Work ...
Страница 72: ...3 3 Periodic Servicing Periodic Servicing Periodic Servicing List ...
Страница 135: ...5 5 Adjustments Adjustments Overview Adjustment Method ...
Страница 175: ...Appendix Service Tools General Circuit Diagram ...