COPYRIGHT © CANON ELECTRONICS INC. 2008 CANON DR-X10C FIRST EDITION
3-15
CHAPTER 3 DISASSEMBLY & REASSEMBLY
3. Main Motor
1) Remove the left cover.
2) Remove the power supply PCB (with a
panel).
3) Remove 2 screws
{
1
(TP head) and re-
move the tension plate
{
2
, tension spring
{
3
and belt
{
4
.
Figure 3-307
4) Remove 3 cable holders
{
1
and remove
the cable
{
2
from the mounting plate.
Remove 3 screws
{
3
(round tips), pull out
the mounting plate
{
4
(with a motor), and
turn it over while holding it with a hand.
Note:
Do not pull it excessively because a
cable is connected.
Figure 3-308
5) Remove the cable holder and connector of
the cable
{
1
and remove the main motor
unit
{
2
from the main body.
Note:
The DC power supply connector for the
cable has a lock.
Figure 3-309