Operating the Video Display
16
Checking Signal Information and Status of the Main Unit
The video display is equipped with a banner display function.
1 Press the jog dial when the OSD menu is closed.
• The channel name, signal information, and status of the main unit will be displayed in the banner. It will
automatically disappear after 6 seconds.
Note
• You can select how the banner is displayed ([Banner]
• You can monitor the input signal status. ([Signal Monitoring]
• For more detailed signal information, please refer to the section on [Signal Information] (
• The [Detecting sync.] banner will continue to appear until the input signal is synchronized.
Operating the video display using an external device [GPI terminal]
You can operate the video display using an external device connected to the GPI terminal and execute the functions
registered in each pin. Remote operation is possible only when the video display is turned on.
Pin layout for GPI terminal
Pin No.
Signal
Factory default
1
Pin1
CH1
2
Pin2
CH2
3
Pin3
CH3
4
Pin4
Time Code
5
Pin5
Tally Green
A tally appears at the
top of the screen.
6
Pin6
Tally Red
7
Pin7
Power On
8
Pin8 (GND)
—
1 Connect an external control device to the GPI terminal.
2 Select
[System Settings] [GPI].
• The pin selection screen will be displayed.
3 Select a pin number and press the jog dial.
4 Select the function to assign.
• See [System Settings] (
70) in the OSD menu for settable functions.
5 Press the jog dial.