OSD Menu
58
Sub Menu
Setting Options (Bold: factory default)
I/PsF
Automatic
Interlace
PsF
Defines how the interlace signal or PsF signal is displayed.
[Automatic]: Automatically determined based on payload and displayed. If
there is no payload, the signal is displayed as an interlace signal.
[Interlace]: Displayed as an interlace signal.
[PsF]: Displayed as a PsF signal.
PsF
Progressive
Interlace
Defines how the PsF signal is displayed.
[Progressive]: Interpolates giving preference to image quality by detecting
paired fields.
[Interlace]: Interpolates using two adjacent fields giving priority to speed.
I/P Conversion
Image Priority
Speed Priority
Sets the interlaced signal I/P conversion method.
[Image Priority]: This mode gives priority to image quality. Processing time
will be longer than [Speed Priority].
[Speed Priority]: This mode gives priority to speed.
Film Cadence
6
2-2
2-3
2-3-3-2
Off
Sets the film cadence mode.
[2-2]: Displays progressive image after conversion for 2-2 pulldown
processed interlaced signal input.
[2-3]: Displays progressive image after conversion for 2-3 pulldown
processed interlaced signal input.
[2-3-3-2]: Displays progressive image after conversion for 2-3-3-2
pulldown processed interlaced signal input.
[Off]: Does not perform film cadence mode progressive conversion.
1
• In the following cases, the maximum magnification is 200% even if [Automatic] is selected.
-
When [Peaking] or [False Color] is [On]
• In the following cases, images are shown in reduced size when [Automatic] is selected.
-
[4096×2160]: When [Image Division] [Square Division] is selected
-
[2048×1080]: When [Image Division] [Multi View (Quad)] or [Multi View (Dual)] is selected
2
Settings are invalid in the following cases:
-
When [Peaking] or [False Color] is set to [On]
-
When an image is zoomed in
3
• The zoom function cannot be used in the following cases:
-
During execution of [Playback File] under [Screen Capture]
-
During display of the test pattern
-
When [Multi View (Quad)] or [Multi View (Dual)] is selected
-
When [Picture Mode] is set differently for the left and right screens and [2020 Constant Luminance] for one of the screens is set to
[Constant Luminance]
• While the zoom function is in use, the following are not displayed:
Background Color, Various markers, Wave Form Monitor, Vector Scope
• When zoom settings are changed, [Frame Hold] turns [Off].
• When the resolution is [2048x1080] or [1920x1080], the display position cannot be changed even if [Magnification] is set to [x2].
• When [Picture Mode] is set differently for the left and right screens, the left screen's [Picture Mode] setting is used.