Chapter 3
3-21
spring base [2]. You can set the
separation pressure to either of 2
settings, determined by the height of the
pressure spring [1] on the spring base
[2].
3.4.4
Upper Registration Roller
3.4.4.1
Removing the
Front Cover
0007-2740
1) Open the feeder cover [1], and remove
the screw [2].
F-3-70
2) Remove the 2 screws [3], and detach the
front cover [4].
F-3-71
3.4.4.2
Removing the
Feeder Cover
0007-2762
1) Remove the screw [1] and the
positioning pin [2]; then, detach the
feeder cover [3].
F-3-72
3.4.4.3
Removing the
Upper Registration
Roller
0007-1623
1) Remove the 4 screws [1], and detach the
open/close guide [2].
[1]
[2]
[3]
[4]
[3]
[2]
[1]