background image

PUB. DIE-0546-000 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

CR-G100 

 

IP Camera Controller 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   

Instruction 

Manual 

Before using the product, carefully read this Instruction Manual and be sure to   
use the product correctly.

 

Retain the Instruction Manual for future reference. 

Содержание CR-G100

Страница 1: ...546 000 CR G100 IP Camera Controller Instruction Manual Before using the product carefully read this Instruction Manual and be sure to use the product correctly Retain the Instruction Manual for future reference ...

Страница 2: ...R G100 IP Camera Controller 9 Standalone Base Adapter 9 3 System Connections 10 Mounting the IP Controller 10 Connecting the Cables 10 Attaching the Ferrite Core to the LAN Cable 12 Connecting the Devices 12 Turning the System On Off 13 4 Configuration 14 Overview of the Verification Process using the Web Setup Tool 14 Starting Up the Web Setup Tool 14 Changing the IP Controller s IP Address 15 Th...

Страница 3: ...ng the Image from Connected Cameras 22 Changing the Main Capture Camera s Shooting Settings 23 Checking the Main Capture Camera s Autofocus and Shutter Operation 23 Checking the System with the Status Screen 24 Setting the System to READY Status 24 Updating the IP Controller s Firmware Version 25 Menu Settings and Operations 26 Robotic Camera Head Settings Menu 26 Menu 28 5 Additional Information ...

Страница 4: ...uct may topple over or fall down resulting in injury and accidents When installing the product in an elevated location make sure to take appropriate measures in advance to prevent the equipment and parts from falling off Equipment falling down may cause serious injury Power supply When the product is connected to a PoE hub power is supplied from the Ethernet terminal Do not use the product if the ...

Страница 5: ...s and humidity humid air entering inside the product may cause malfunctions and condensation Transportation Installation Do not install the product on an unstable surface or in locations exposed to severe vibration This may cause the product to topple over or fall down resulting in injury Do not install the product in locations directly exposed to salt water or where corrosive gases or oily smoke ...

Страница 6: ...ing the product for the customer s purpose 3 Canon shall make no guarantees about the results obtained using this product 4 The product specifications configuration and appearance are subject to change without prior notice 5 For further information on repairs maintenance or adjustments not mentioned in this instruction manual contact a Canon sales representative 6 Note that Canon may be unable to ...

Страница 7: ...Camera Remote application you can control multiple robotic camera systems and EOS cameras You can also use a controller to operate the system and check a streamed image with a very small lag while recording For details about using the software refer to the Camera Remote Application Operation Guide Make sure to always use the latest IP controller s firmware version A 25 and Camera Remote applicatio...

Страница 8: ...requires adequate knowledge about configuring and using wired Ethernet networks Canon cannot provide support regarding network configurations Conventions Used in this Document Information and precautions that is important you follow Additional information you should know A Reference page number Camera head refers to the CR S700R Robotic Camera Head unit IP controller refers to the CR G100 IP Camer...

Страница 9: ...al 8 VIEW CAMERA terminal 9 N3 Remote terminal 10 Ethernet 1000 Mbps link indicator A 11 11 Ethernet 100 Mbps link indicator A 11 12 USB terminal reserved extension port A 28 13 Power status indicator A 13 14 Power switch A 13 29 Refer to Connecting the Cables A 10 Standalone Base Adapter 1 Screw holes for tripod mounting screws 1 4 x3 2 Screw holes for tripod mounting screws 3 8 x3 12 1 2 3 4 5 9...

Страница 10: ...ter is facing the IP controller s power switch and secure it in place using hex head bolts M3 x4 When using the screw holes for tripod mounting make sure the length of the mounting screws does not exceed 10 mm 0 39 in Connecting the Cables Use the following diagram as a reference to connect the IP camera controller to the main capture camera and other devices It shows a connection example where th...

Страница 11: ... Ethernet indicators A 9 When the Ethernet connection can be used at a transfer rate of 1000 Mbps or 100 Mbps the corresponding Ethernet indicator will illuminate in green The indicator will flash while data is being transferred 6 DC coupler and AC adapter battery PoE hub Control PC 8 AC adapter FTP server 2 LAN cable 1 USB Type C cable Main capture camera sold separately 7 LAN cable 3 N3 cable su...

Страница 12: ...apture camera 2 using a LAN cable 4 Connect the IP controller s N3 Remote terminal and the remote control terminal on the main capture camera 3 using an N3 cable 5 When using a wide view camera connect its USB cable to the IP controller s VIEW CAMERA terminal 4 6 When using an eyepiece camera connect its USB cable to the IP controller s EYEPIECE CAMERA terminal 5 7 Insert a battery pack into the m...

Страница 13: ...lluminate Turning the system off When the IP controller s power is on slide the power switch once in the direction of the arrow The green power status indicator will turn off and the orange indicator will start flashing two flashes per second When the IP controller s shutdown process is completed the orange indicator will stop flashing and the IP controller will turn off While the IP controller is...

Страница 14: ...era head Check the motion range for pan tilt roll zoom operations and adjust the motion range values as necessary 7 Set the shooting settings on the main capture camera and check the shutter operation 8 Only when using a camera head Perform the camera head s homing procedure again 9 Set the system to READY status to set it in standby mode for the main shooting session 10 Log out from the system 11...

Страница 15: ...Launch the web browser and access the URL as in step 1 This time use the IP address that you set in step 3 When the login screen is displayed you can bookmark the web page in the web browser 5 Enter the user name and password and click Login The user name is admin Log in with the password that you set in step 2 Changing the IP Controller s IP Address 1 Enter the desired IP address other than 192 1...

Страница 16: ...reen 16 The Web Setup Tool Screen 1 Register tab Settings for registering connected devices 2 Operation tab Main operation panel 3 Status tab Status information 4 Robotic Camera Head Settings menu button 5 Menu button 6 Display Setup area ...

Страница 17: ... enter any text string up to 100 characters that will be used as model name 4 Register button Checking and Registering Connected Devices 1 Check the connection status and model name of the connected devices If the status of the connected device is shown as Disconnected or if the model name is not displayed check that the device is turned on and correctly connected 2 Only when using a camera head E...

Страница 18: ...Camera head control area 7 Shooting control area Homing the Camera Head When using a camera head click Homing to perform the camera head s homing procedure and mechanically reset the camera head s pan tilt roll and zoom to their initial positions pan roll 0 tilt 90 zoom 0 wide angle end Be sure to perform the homing procedure immediately after turning on the camera head and just before turning it ...

Страница 19: ...ed instead Switching to Underslung Mode If the camera head is installed in underslung position set Underslung mode to the ON position When the system is set to underslung mode the direction of pan tilt movements is reversed Setting the Camera Head s Motion Range Set the limits for the camera head s pan tilt roll and zoom motion The homing position does not change even after setting the camera head...

Страница 20: ...tilt up and down respectively The directions are reversed in underslung mode 1 Click to tilt down until the desired end of the motion range and then click Down Limit to confirm the motion limit 2 Similarly click to tilt up until the desired end of the motion range and then click Up Limit to confirm the motion limit 3 Click Save to save the motion range values Setting the Roll Motion Range Click or...

Страница 21: ... and enable operation beyond the limits that were set The changes are not saved to the IP controller However the current motion range adjustments displayed on the screen are maintained so this is a convenient way to change only some of the motion range limit values Resetting the Motion Range Limits Click Clear to reset the motion range limits to their initial values Use this option to clear the mo...

Страница 22: ...xes to the positions stored in the preset position file Checking the Operation of the Main Capture Camera Launch the web setup tool on the control PC to check the system s operation and configure the necessary settings When using the Camera Remote application for a shooting session launch also the Camera Remote application to check its correct operation in advance When using the system without a c...

Страница 23: ... control interface from the shutter release mode pulldown menu N3 N3 Remote USB or Head camera head interface 2 Click Autofocus to focus automatically if necessary The autofocus operation stops after about 3 seconds 3 Click the capture button to release the shutter The photo is recorded on the card If the FTP transfer function was correctly configured the image file is transferred also to the FTP ...

Страница 24: ...ed devices registered and their connection status as well as the motion range limits on all axes You can also set the IP controller to READY status or clear this status Setting the System to READY Status Click Set READY in the Status screen to switch the system to READY status standby for the main shooting session Click Clear READY to clear the READY status Check that the system is in READY status...

Страница 25: ...download from the local Canon website 2 Click menu Update firmware The current firmware version will be displayed 3 Click Update and select the firmware update file Select the folder on the control PC where you saved the firmware update file 4 Click OK to update the firmware The firmware is updated and the IP controller restarts if necessary 5 Click menu Update firmware again to check the updated ...

Страница 26: ...0 1000 High 20 to 12000 10000 Tilt speed 20 12000 Low 20 to 12000 100 Medium 20 to 12000 1000 High 20 to 12000 10000 Roll speed 20 12000 Low 100 to 9000 100 Medium 100 to 9000 500 High 100 to 9000 5000 The maximum pan tilt roll speed is determined by the Speed control max velocity setting under the Control tab Zoom speed 0 7 Low 0 to 7 0 Medium 0 to 7 2 High 0 to 7 7 Restore Default Settings Click...

Страница 27: ...e setting remove the checkmark from the Default box Pan 45 150 Tilt 45 150 45 to 150 45 Roll 45 113 45 to 113 45 Restore Default Settings Click this button to reset all the settings in the same tab to their initial values The changes are not saved until you click OK In most cases use the default maximum speed and acceleration values set in the Control tab settings If the Control tab s maximum spee...

Страница 28: ...mware A 25 Maintenance Power Control Camera Eyepiece camera Wide view camera Extension Port On Off Turn on off the power to the main capture camera eyepiece camera wide view camera and extension USB port respectively Console Command Log Reserved for system maintenance Reboot Restarts the IP controller Restore Factory Settings Resets all the IP controller s setting to their initial values Download ...

Страница 29: ... in the wrong direction Activate the underslung mode on the IP controller A 19 The main capture camera is not working properly An unknown error may have occurred Turn the main capture camera off and then on again If using the system with a camera head you can also click menu Maintenance Power Control Camera to turn the camera off on A 28 Communication with the main capture camera has stopped Disco...

Страница 30: ... be discarded Failed to restore the factory setting The IP controller could not reset the settings using the menu command Reset the IP controller s settings to their initial values using the power switch A 30 Failed to upload the firmware The firmware could not launch correctly Turn the IP controller and the connected devices off and then on again A 13 Launch the web setup tool A 14 and try the op...

Страница 31: ... EYEPIECE CAMERA terminal USB 3 0 SuperSpeed Type A connector VIEW CAMERA terminal USB 2 0 Hi Speed micro B connector Ethernet terminal Ethernet 1000BASE T compatible RJ45 connector compatible with PoE power supply Power supply Via PoE function Compatible with PoE power supply through the LAN connector compliant with IEEE802 3at Type 1 Type 2 standard Class 4 device 30 0 W demanded vis à vis the p...

Страница 32: ...s instructions and its focus is correctly adjusted The IP controller is correctly connected to a network and power supply at the shooting location Web setup tool The password and network settings were correctly configured after turning on the IP controller Connected devices are correctly registered Underslung mode is turned on off according to the installation position The camera and lens are corr...

Страница 33: ...6 Appendix Detailed Dimensions 33 Detailed Dimensions CR G100 IP Camera Controller 38 2 34 4 114 3 105 31 4 96 attachment pitch 141 6 132 6 attachment pitch 122 ...

Страница 34: ...6 Appendix Detailed Dimensions 34 Standalone Base Adapter 105 57 5 42 5 10 4 5 4 5 132 6 30 30 141 6 70 8 4x M3 through hole for attachment to the IP Camera Controller 3x 1 4 9 3x 3 8 9 ...

Страница 35: ...inal 9 11 31 Ferrite core 12 Firmware update 25 Handling precautions 5 HEAD terminal 9 31 Homing 14 18 26 Importing motion range settings 21 IP address 14 15 IP camera controller 10 33 Login 14 Main capture camera 10 22 Menu settings 26 28 Message list 30 Mounting 10 Motion range 19 21 Motion speed 20 26 Operation environment 31 Pan 20 Password 14 PoE hub 11 Power supply 31 Preset positions 22 REA...

Страница 36: ...the operation of the main capture camera 22 Tilt 20 Troubleshooting 29 Turning the IP controller on off 13 Underslung mode 19 URL 14 User name 14 VIEW CAMERA terminal 9 11 31 Web setup tool 14 Wide view camera 7 10 Zoom 21 ...

Страница 37: ... CANON INC 2020 Canon Inc 30 2 Shimomaruko 3 chome Ohta ku Tokyo 146 8501 Japan The information in this document is verified as of January 2020 Subject to change without notice ...

Отзывы: