5
5
5-137
5-137
Adjustment > Auxiliary Adjustment > Side registration position fine adjustment mode (shift amount change) > Procedure
Adjustment > Auxiliary Adjustment > Side registration position fine adjustment mode (shift amount change) > Procedure
■
Procedure
1) Set DIP SW382 [1] on the Switch PCB as shown in the figure below.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
2) Press the Push Switch SW385 [1] to complete preparation for the adjustment.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
F-5-338
F-5-339
3) By pressing the Push Switch SW383 [1] or SW384 [2], mode can be selected.
Every time SW384 [2] is pressed, "A: Mode setting/B: Adjustment value setting" is displayed
on LED [3].
Display [A] on LED [3] (select the mode setting mode).
4) Press the Push Switch SW385 [1] to determine the mode.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
[2]
[4]
[3]
5) By pressing the Push Switch SW383 [1] or SW384 [2], mode setting can be changed.
Every time SW384 [2] is pressed, "0: Disabled/1: Enabled stitching only/2: Enabled non-
stitching only/3: Enabled stitching/non-stitching" is displayed on LED [3].
6) Press the Push Switch SW385 [4] to determine the mode.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
[2]
[4]
[3]
F-5-340
F-5-341
Содержание Booklet Finisher-D1
Страница 12: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Страница 14: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Страница 60: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Страница 177: ...5 5 Adjustment Adjustment Basic Adjustment Adjustment at Time of Parts Replacement Auxiliary Adjustment ...
Страница 315: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Страница 357: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...