Menu Settings
134
Submenu
Function
Adjust panel
temperature
Used when the gamma has changed in response to other changes,
such as changes in ambient temperature.
Compensates for changes in gradation caused by a change in LCOS
panel temperature. This function can only be used after about 2 minutes
of projection.
Light source
calibration
Use when there is concern about deterioration of the color and
luminance of the light source due to extended use.
Trigger out
Operation of a screen or other external device can be triggered by turning the projector on or
off.
Option
Function
Off
No output from the trigger terminal.
Link with power
12 V of voltage output from the trigger terminal during projection. Used
to trigger operation of a screen or other external device in sync when
the projector is turned on or off.
Air filter counter
Shows a counter to remind you when to replace the air filter.
Also shows a counter reset screen.
Power counter
Indicates the total time that the projector has been connected to a power supply.
Option
Function
Off
Do not adjust the panels to suit the temperature.
Adjust
Adjust the panels to suit the temperature.
Option
Function
OK
Execute light source calibration.
Cancel
Do not execute light source calibration.
Light source calibration can only be used after about 30 minutes of projection.
• After air filter replacement, reset the air filter counter.
• For details on replacing the air filter, see
This value is not reset even if [Factory defaults] is executed.