4-11
Chapter 4 Other Functions
4.
User Mode Functions
The following functions are available in the User Mode.
■
Buzzer (Beeper) Control Setting
The beeper (“buzzer”) sounds when you press the control
panel keys and when a scanning error occurs.
ON2:
The beeper sounds when a scanner error occurs.
ON1:
The beeper sounds when a scanner error occurs, and
when a control panel key is pressed.
OFF:
The beeper never sounds.
■
Double-Feed Control Setting
Select whether double-feed detection is enabled when the
Count-Only mode is enabled. If you set DFD Control to
[ON], double feeds are detected during feeding in the
Count-Only mode.
■
Double-Feed Retry Setting
When a double feed is detected with Ultrasonic double-
feed detection, the Double-Feed Retry function transports
the double fed pages back to the feeder inlet and tries
scanning again.
IMPORTANT
• You can specify the number of times to retry. When double
feeding continues to be detected after retrying the specified
number of times, an error message is displayed and scanning
stops after the document is ejected at the eject outlet.
• Pre-imprinter printing is only available when the scanner’s
Double-Feed Retry function is set to OFF.
■
Staple Detection Setting
Select whether staple detection is enabled when the Count-
Only mode is enabled.
(See “Staple Detection Function”
ON:
Detects staples in the Count-Only mode.
OFF:
Does not detect staples in the Count-Only mode.
■
Staple Detection Level Setting
Sets the staple detection sensitivity level.
[1] is the default setting, [2] provides higher sensitivity,
and [0] provides lower sensitivity.
■
Long Document Mode Setting
You can enable this mode to detect and scan document
pages up to 118.1" (3 m) long when the Auto Detection
page size setting is selected.
ON2:
Automatically detects page sizes when scanning
documents up to 118.11" (3 m) long.
ON1:
Automatically detects page sizes when scanning
documents up to 39.37" (1 m) long.
OFF:
Automatically detects page sizes when scanning
documents up to 17.01" (432 mm) long.