Cannon CANTERBURY CANTIB-02-NG Скачать руководство пользователя страница 1

CANNON

CANTERBURY INBUILT

CANTIB-02-NG AND CANTIB-02-LP

TO SUIT MOCK FIREPLACE INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR FITMENT

INTO A COMBUSTIBLE ENCLOSURE

This heater is for use with Natural and Propane gases.

Read these instructions in conjunction with heater

installation instructions

SPACE
HEATER

GAS LOG

FIRE

REF:

 F2663-E 

CANTERBURY IB MOCK INSTALLATION INSTRUCTION.CDR

REVISION “E”                                                                                          DATED: APRIL 2007

Содержание CANTERBURY CANTIB-02-NG

Страница 1: ...SUIT MOCK FIREPLACE INSTALLATIONS INSTALLATION INSTRUCTIONS FOR FITMENT INTO A COMBUSTIBLE ENCLOSURE This heater is for use with Natural and Propane gases Read these instructions in conjunction with...

Страница 2: ...OMMENDATIONS age 2 MOCK CAVITY DIMENSIONS age 3 P 4 ag OVERALL DIMENSIONS OF INSERT CABINET P e ge FITMENT OF SPACER BRACKETS AND BLANKET Pa 5 INSTALLATION INTO WALL CAVITY METHOD A Page 6 7 P INSTALL...

Страница 3: ...LF WITH THE CORRECT INSTALLATION METHODS CORRECT FLUE DESIGN AND ALLOWANCE FOR VENTILATION MUST BE CONSIDERED AVOID THE USE OF FLUE BENDS IF POSSIBLE ALWAYS ALLOW FOR THE COMPLETE REMOVAL OF THE HEATE...

Страница 4: ...EATER WILL NEED TO BE CONSTRUCTED THE HEATER MUST SIT ON A SOLID SEALED BASE AND THE ENCLOSURE MUST BE SEALED FROM ANY DRAUGHTS AND BE INSULATED AS NECESSARY TO ELIMINATE LOW TEMPERATURES OUR BROCHURE...

Страница 5: ...STIBLE SURFACES 20 mm CLEARANCE FROM BOTH TOP AND SIDE SURFACES 50 mm CLEARANCE FROM REAR 100 mm CLEARANCE BETWEEN SIDE OF THE HEATER FRONT AND COMBUSTIBLES ADDITIONAL CLEARANCES ARE SPECIFIED IN THE...

Страница 6: ...DEPTH WITH TRANSITION ADAPTOR FITTED 425 mm 620 mm 350mm 425mm THE HEATER FOR INSTALLATION INTO A MOCK FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS SEE FIG 5 F1417 FLUE TRANSITION ADAPTOR F1404 REAR...

Страница 7: ...CABINET ON DIAGONAL CORNERS AS SHOWN SEE FIG 5 3 POSITION INSULATION BLANKET ON HEATER TOP ALIGNED WITH EDGES SECURE WITH MASKING TAPE AS SHOWN SEE FIG 5 FIXING SCREWS No8 x 3 8 SELF TAPPING D I A G...

Страница 8: ...HROUGH HEADER FLANGES AT STUD CENTRES AND USE CLOUTS OR SCREWS TO ATTACH TO WALL 6 MEASURE DISTANCE FROM FLOOR TO TOP OF FLUE OUTLET OF THE HEATER 7 ADJUST ELBOW TO THE DISTANCE MEASURED PLUS 2 mm AND...

Страница 9: ...E FLUE SUPPORT FLUE ADAPTER FLASHING FLUE CLAMP FLUE COWL APPROVED TO AG604 ROOF CLADDING 100 mm DIA FLUE PIPE MAINTAIN 25 mm CLEARANCE BETWEEN FLUE AND WOODWORK WALL CLADDING 12 mm FROM BOTTOM OF WAL...

Страница 10: ...ROM ALL COMBUSTIBLES INSULATION BLANKET HEATER 100 mm DIA SINGLE SKIN FLUE FLUE TO FIT INSIDE OF SPIGOT FIT TWO LENGTHS OF VERTICAL FLUE 1 8 M BEFORE FITTING ANY BENDS IF BENDS ARE USED FIT INSIDE OF...

Страница 11: ...MAINTENANCE IF YOUR HEATER REQUIRES ATTENTION CONTACT SAMPFORD AND STAFF PTY LTD ON PH 1300 727 421 or FAX 1300 727 425 Page 9 7...

Страница 12: ...REF F2663 E CANTERBURY IB MOCK INSTALLATION INSTRUCTION CDR REVISION E DATED APRIL 2007...

Отзывы: