C&H
Technologies, Inc.
•
445 Round Rock West Drive
•
Round Rock, TX 78681-5012
(512) 733-2621
•
FAX (512) 733-2629
•
www.chtech.com
Inputs/Outputs:
•
Pulse Input
•
True Output A
•
True Output B
•
Complement Output A
•
Complement Output B
•
External Power (+36V)
•
External Power Interlock
•
Pulse Interlock
External Power
:
36V 2A supply required
Front Panel Connectors:
Pulse Input/Outputs
SMA
Ext. Pwr. & Interlocks 9-pin DSUB
Temperature:
Operating:
0
°
C to 50
°
C
Storage:
-40
°
C to 70
°
C
Power (typical):
+5V
150
mA
+12V
300
mA
-12V
100
mA
Ext. +36V
1.0 A
M Module Compliance
Complies with ANSI/VITA Std. 12-
1996 for triple-wide MA Modules
Data Transfers:
16 bit
Interrupts:
not supported
Triggers:
not supported
Compatible with VXI, VME, PCI,
cPCI and other M Module carriers.
Applications
•
Pulse amplification
•
Pulse level shifting
Ordering Information
Part Number
11028470-0001
Additional Information
User Manuals for C&H carriers and
this module can be found on our
website at www.chtech.com.
Specifications:
Outputs:
Two true (A & B) and two
complement (A & B) outputs
Frequency:
20MHz
max.
Input:
TTL
Output Amplitude:
R
LOAD
= 50
Ω
+0.21V to +15V
R
LOAD
=
∞
+0.42V to +30V
Output Current:
Source
300mA
Sink
100mA
Output Impedance:
50
Ω
Programming Resolution:
10V
range
2.50mV
30V
range
7.50mV
Accuracy:
±
0.75%
±
75mV
Rise/Fall Time:
30V,
R
LOAD
=
∞
30ns
M206
Pulse Amplifier
The M206 is a programmable pulse
amplifier that accepts a fixed level
input pulse and provides dual
complementary switched outputs.
The module produces a total of four
outputs. Two outputs have the
same active-level as the input pulse
and two outputs have the
complement level of the input pulse.
The output level is programmable
up to 30V into no load (up to 15V
into a 50
Ω
load). An ex36V
supply is required. An external
power interlock and a pulse interlock