Canaropa 9500FL Скачать руководство пользователя страница 1

CAUTION:
Exit device components must be 
installed flush to a flat surface

RIGHT HAND REVERSED 

LEFT HAND REVERSED

OUTSIDE

OUTSIDE

To change hand of device: use 2 1/4" (57.2 mm) long pin to
knock out lift lever pin, remove lift lever and reassemble at other
end of main chassis assembly by reinserting lift lever pin
(see figure below) 

Lift
lever
pin

Use 2 1/4" long pin
to knock out lift lever
pin and re-orient lift
lever (as shown)

Lift
lever

Lift
lever
pin

DOOR HANDING

HANDING CHANGE INSTRUCTIONS

9500

SERIES

9500FL  EXIT DEVICE - FIRE RATED (F) LESS BOTTOM SURFACE ROD (L)

 

INSTALLATION INSTRUCTIONS

9500FL-INST-EN-R2016-09 1/2

Top latch

chassis

assembly

Latch

release

Rail assembly

Push / touch pad

Sliding cover
If Alarm Panel or Request for Exit 
is used refer to the installation 
instructions supplied with these kits.

End cap

Top latch

chassis cover

Top rod

Top rod

guide

Main

chassis

assembly

Vertical
Reference
Line

Main 

chassis

cover

Lift arm

LEFT HAND REVERSED SHOWN

Auxiliary fire latch assembly

Rail mounting
bracket

Through bolt
sexnut

GENERAL NOTES 

Before installing exit device, verify or note the following:

1.  Fire exit hardware is to be installed only on fire doors bearing the marking "Fire Door To Be Equipped with Fire 

Exit Hardware".

2. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the 

opening. The exit device manufacturer makes no representations or warranties concerning what such impact may 
be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and 
installing a new fire rated opening, please consult with a code specialist or local code official (Authority Having 
Jurisdiction) to ensure compliance with all applicable codes and ratings.

3.  The door surface must be flat and properly reinforced at the exit device mounting locations. If door is not 

reinforced, the door surface may collapse or bow-in, causing malfunction in the exit device operation.

4.  Door must be properly fitted and hung.
5.  The 3' exit device model can be cut to fit doors from 30 to 36" (762 to 914 mm) in width (refer to section 5 on page 2).

The 4' exit device model can be cut to fit doors from 36 to 48" (914 to 1219mm) in width (refer to section 5 on page 2).

6.  Determine door handing (see illustration below). Exit device is handed. If handing change is required refer to handing 

instructions below.

7.  For wood doors or hollow metal doors use through bolts, and for metal reinforced doors drill & tap and use machine screws. 

(Refer to template document).

Machine

screws

Top latch 

strike

Thru-bolt

sexnuts

Thru-bolt

sexnuts

Horizontal
Reference
Line