9500FV EXIT DEVICE - FIRE RATED (F) SURFACE VERTICAL RODS (V)
INSTALLATION INSTRUCTIONS
Top latch
strike
CAUTION:
Exit device components must be
installed flush to a flat surface
RIGHT HAND REVERSED
LEFT HAND REVERSED
OUTSIDE
OUTSIDE
To change hand of device: use 2 1/4" (57.2 mm) long pin to
knock out lift lever pin, remove lift lever and reassemble at other
end of main chassis assembly by reinserting lift lever pin
(see figure below)
Lift
lever
pin
Use 2 1/4" long pin
to knock out lift lever
pin and re-orient lift
lever (as shown)
Lift
lever
Lift
lever
pin
DOOR HANDING
HANDING CHANGE INSTRUCTIONS
9500FV-INST-EN-R2016-09
1/2
Vertical
reference
line
LEFT HAND REVERSED SHOWN
9500
SERIES
GENERAL NOTES
Before installing exit device, verify or note the following:
1. Fire exit hardware is to be installed only on fire doors bearing the marking "Fire Door To Be Equipped with Fire
Exit Hardware".
2. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the
opening. The exit device manufacturer makes no representations or warranties concerning what such impact may
be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and
installing a new fire rated opening, please consult with a code specialist or local code official (Authority Having
Jurisdiction) to ensure compliance with all applicable codes and ratings.
3. The door surface must be flat and properly reinforced at the exit device mounting locations. If door is not
reinforced, the door surface may collapse or bow-in, causing malfunction in the exit device operation.
4. Door must be properly fitted and hung.
5. The 3' exit device model can be cut to fit doors from 30 to 36" (762 to 914 mm) in width (refer to section 5 on page 2).
The 4' exit device model can be cut to fit doors from 36 to 48" (914 to 1219mm) in width (refer to section 5 on page 2).
6. Determine door handing (see illustration below). Exit device is handed. If handing change is required refer to handing
instructions below.
7. For wood doors or hollow metal doors use through bolts, and for metal reinforced doors drill & tap and use machine screws.
(Refer to template document).