READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive 

or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.

Cod

0060302209

Model

CEPD140-4

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 

from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent 

warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to 

prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by 

the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning   

Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f ). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit 

(ceiling installation only). 

h). This unit must be grounded. 

 i). Not for Use in Kitchens.

 j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or 

ceilings or into attics, crawl spaces, or garages.

k). 

WARNING: 

To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

 l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

    

DO NOT MOUNT THIS PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

See “CONNECT ELECTRICAL WIRING” for details.

The control box, located inside the fan housing: 

(1) The low airflow knob adjusts the lower airflow from 40CFM up to the air flow 

rate of the high fan speed (For CEPD140-4, the high fan speed is determined by 

the toggle switch setting). The fan will not work when the knob turned between

OFF-40CFM.

(2) The time delay knob is adjustable from 3 to 30 minutes and will switch the fan 

to the low speed setting after the switch is turned off for the set period of time. 

(3) The toggle switch will adjust the upper fan speed setting from 80 to 140 CFM.

(Only for CEPD140-4)

Fan will run at the user-adjustable airflow rate continually;

turn on the switch, fan will turn to high speed;

turn off the switch, fan will continue to run at the certified airflow rate until the 

user-adjustable time delay has passed, and then will automatically change to the 

user-adjustable airflow rate.   

VENTILATION FANS

1 2 3

Toggle switch

(only for CEPD140-4)

Control Box

Low airflow 

knob

is the position of switch

time delay  

knob

140

1 2 3

Switch position

Airflow (CFM)

110

1 2 3

90

1 2 3

80

1 2 3

T

S

Max.

40CFM

30min

10min

20min

3min

140

1 2 3

Switch position

Airflow (CFM)

110

1 2 3

90

1 2 3

80

1 2 3

1 2 3

OFF

50%

70%

CEPD150

CEPD200

www.canarmna.com