5 Unpackaging and Inspection 

 

  5 / 19 

 

5 Unpackaging and Inspection 

Before unpacking the inverter, check the package appearance thoroughly, such as for holes and cracks, and check the 
inverter model accordingly. If you discover any damage to the packaging which indicates the inverter may have been 
damaged, or the inverter model is not the one you requested, do not unpack the product and contact your dealer 
immediately. 
After opening the package, check all of the accessories carefully in the carton. If any damage is found or any 
component is missing, contact your local installer. 
Note: For details information about the components, see the packing list document in the packing case. 

6 Installation 

6.1 Basic Installation Requirements 

1) Do not install the inverter on the structures constructed of flammable, thermolabile or explosive materials. 
2) The installation surface must be strong enough to bear the inverter's weight for a long period time. (Please check 
the inverter’s weight in the product specification of ANNEX B). 
3) The inverter is protected to IP65, can be installed indoors and outdoors. 
4) The humidity of the installation location should be below 100% without condensation. 
5) The ambient temperature should be between -25°C to 60°C. 
6) Install at eye-level for easy operation. 
7) Do not install the inverter near television antenna or any other antennas and antenna cables. 
8) Ensure the inverter is out of children's reach. 
9) Install inverter at the locations with some cover or protection, to ensure the optimum operation. 

                   

 

FIG.6-1 Inverter Installation Positions                            FIG.6-2 Forbid to Install in Small Closed Cabinet 

10) Do not install in small closed cabinet where air cannot circulate freely. Do not put any other objects on the inverter, 
as per FIG.6-2. 
11) Comply with the Min. clearance to walls, other inverters, or objects to ensure the installation and maintenance, 
meanwhile for the good heat dissipation.   

 

     

FIG.6-3 Installation Clearance Requirement 

Direction 

Min. clearance (cm) 

Above 

50 

Below 

50 

Sides 

30 

Front 

30 

Содержание CSI-3.68K-S22002-E

Страница 1: ...CSI 3K S22002 E CSI 3 68K S22002 E CSI 5K S22002 E PV Inverter User Manual Part No 2809002601 Release Date October 2021...

Страница 2: ...ew 3 3 1 Product Introduction 3 3 2 Appearance 3 3 3 Product Nameplate 4 4 Storage 4 5 Unpackaging and Inspection 5 6 Installation 5 6 1 Basic Installation Requirements 5 6 2 Mounting Wall mounting Br...

Страница 3: ...s 14 9 5 Switch off 14 10 Daily Maintenance 15 11 Trouble Shooting 15 11 1 Warning 15 11 2 Errors 15 12 Handling the Inverter 17 12 1 Removing Inverter 17 12 2 Packing Inverter 17 12 3 Disposing Inver...

Страница 4: ...roduct lists and documents published on our website at http www csisolar com as these lists are updated on a regular basis 1 3 Limitation of Liability CSI Solar Co Ltd shall not be held responsible fo...

Страница 5: ...liar with the safety specification about the electrical system 3 Be familiar with the local requirements rules and regulations 4 Understand the composition and working principles of the grid tied PV s...

Страница 6: ...itch Inverter AC Switch Electricity Meter Utility Grid FIG 3 1 PV Power System Diagram 3 2 Appearance Front view and bottom view A B C DE F GH A C B F E D GH C B I F E D G H CSI 3K S22002 E CSI 3 68 5...

Страница 7: ...00 LED Indicators Normal Waiting Steady Green Blinking Green No DC Input Off Error Steady Red More details please refer to the user manual Scan the QR code 624300XXXX FIG 3 3 Inverter Nameplate for re...

Страница 8: ...rter s weight for a long period time Please check the inverter s weight in the product specification of ANNEX B 3 The inverter is protected to IP65 can be installed indoors and outdoors 4 The humidity...

Страница 9: ...litate heat dissipation and to ensure that no moisture can penetrate the product 15 FIG 6 5 Installation Angle Requirements 13 Do not install the inverter outdoors in salt sulfur or other corrosive ar...

Страница 10: ...lling Positions 2 Drill expansion anchors into the corresponding four holes and then secure the bracket by using screws as per FIG 6 7 FIG 6 8 FIG 6 7 Install Expansion Anchors FIG 6 8 Fix Wall mounti...

Страница 11: ...pplied 7 3 Meter CT Connection Optional The inverter has integrated export limitation functionality To use this function a power meter or a CT must be installed For installation and operation methods...

Страница 12: ...d AC circuit breaker specifications are as follows Inverter type AC circuit breaker specifications CSI 3K S22002 E 25 A CSI 3 68K S22002 E 25 A CSI 5K S22002 E 32 A Recommend maximum AC cable length I...

Страница 13: ...0 8N m PE L N L N PE A A A A DEVALAN type Torque 1 4N m L N PE B B B B N PE L FIG 7 5 AC Terminal Positions 3 Push the threaded sleeve into the plug screw the press nut tightly EXCEEDCONN type DEVALAN...

Страница 14: ...value of the inverter Note Consider temperature coefficient of the PV modules Check the inverter specification in section ANNEX B 7 6 2 Wiring Negative Coupler Contactor Pin Positive Coupler Contacto...

Страница 15: ...bottom terminal of the inverter until one sound click audibly The locked DC connectors can only be disconnected with special tool FIG 7 14 Illustration of DC Ports 7 6 3 Connecting PV array DC input D...

Страница 16: ...narios to operate as per FIG 8 2 1 Standard Mode Connect to internet and operate the inverter through CSI cloud web or App 2 Local Mode Connect and operate the inverter locally without internet Soluti...

Страница 17: ...cally when the DC input voltage meets the performance requirement of the utility grid Normally there will be three statuses during the operation refer to the LED indications 1 Waiting Conditions The i...

Страница 18: ...ndertaken in the absence of proper tools test equipment or the more recent revision of the manual with has been clearly and thoroughly understood Items Methods Period System clean Check the temperatur...

Страница 19: ...ect the AC connector turn on DC Switch inverter will restore the grid connection automatically 4 If error message still exists contact Customer service F 107 DC component over range 1 Restart inverter...

Страница 20: ...h sides of the inverter 4 Remove the inverter from the bracket Note Before performing any work ensure that you are familiar with this document 12 2 Packing Inverter If possible use the original packag...

Страница 21: ...DC direct current LED light emitting diode MPPT maximum power point tracking PC personal computer PE protecting earthing PV photovoltaic RCD residual current protective device RCM residual current ope...

Страница 22: ...8 97 5 98 0 European Efficiency 97 1 96 8 97 5 MPPT Efficiency 99 9 99 5 99 9 Safety Protection DC Switch Integrated Anti Islanding Protection Integrated DC Reverse Protection Integrated Insulation Mo...

Страница 23: ...ngsu China 215129 Sales Inquiries Email sales emea csisolar com Customer Support Email service emea csisolar com This manual is subject to change without prior notification Copyright is reserved Dupli...

Страница 24: ...ANNEX C CE RoHS Declaration...

Страница 25: ......

Страница 26: ...ANNEX D REACH Declaration...

Страница 27: ......

Страница 28: ......

Отзывы: