CanadianSolar CSI-3.68K-S22002-E Скачать руководство пользователя страница 4

1 Introduction 

 

  1 / 19 

 

1 Introduction 

1.1 General Information 

This manual provides important safety information on relating to the installation, maintenance and usage of single 
phase PV inverters. Both users and professional installers must read these guidelines carefully and strictly follow these 
instructions. Failure to follow these instructions may result in death, serious injury or property damage. 
Only qualified professionals and service personnel can do the installation and operation (refer to 62109-1). Installers 
must inform end-users (consumers) about the aforesaid information accordingly. 
This manual is only valid for the PV inverter types, CSI-3K-S22002-E, CSI-3.68K-S22002-E, and CSI-5K-S22002-E 
produced by CSI Solar Co., Ltd. 

1.2 User Manual Disclaimer 

The information contained in this manual is subject to change by CSI Solar Co., Ltd. without prior notice. CSI Solar Co., 
Ltd. gives no warranty of any kind whatsoever, either explicitly or implicitly, with respect to the information contained 
herein. 
In the event of any inconsistency among different language versions of this document, the English version shall 
prevail. Please refer to our product lists and documents published on our website at: http://www.csisolar.com as these 
lists are updated on a regular basis. 

1.3 Limitation of Liability 

CSI Solar Co., Ltd. shall not be held responsible for damages of any kind, including-without limitation-bodily harm, 
injury or damage to property, in connection with handling PV inverters, system installation, or compliance or 
non-compliance with the instructions set forth in this manual.   

1.4 Target Group 

This document is intended for installers and users. 

1.5 Symbol Conventions 

The symbols that may be found in this document or on the product packaging are defined as follows. 

1.5.1 Warnings in the manual 

A warning describes a hazard to equipment or personnel. It calls attention to procedure or practice.   
 

Symbol 

Description 

 

DANGER 

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death 

or serious injury.   

 

WARNING 

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death 

or serious injury.   

 

CAUTION 

CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor 

or moderate injury.   

 

NOTICE 

NOTICE indicates a situation which, if not avoided, could result in equipment or property 

damage. 

 
 
   

Information 

Information indicates that you must read carefully to ensure optimal operation of the system.   

 

Содержание CSI-3.68K-S22002-E

Страница 1: ...CSI 3K S22002 E CSI 3 68K S22002 E CSI 5K S22002 E PV Inverter User Manual Part No 2809002601 Release Date October 2021...

Страница 2: ...ew 3 3 1 Product Introduction 3 3 2 Appearance 3 3 3 Product Nameplate 4 4 Storage 4 5 Unpackaging and Inspection 5 6 Installation 5 6 1 Basic Installation Requirements 5 6 2 Mounting Wall mounting Br...

Страница 3: ...s 14 9 5 Switch off 14 10 Daily Maintenance 15 11 Trouble Shooting 15 11 1 Warning 15 11 2 Errors 15 12 Handling the Inverter 17 12 1 Removing Inverter 17 12 2 Packing Inverter 17 12 3 Disposing Inver...

Страница 4: ...roduct lists and documents published on our website at http www csisolar com as these lists are updated on a regular basis 1 3 Limitation of Liability CSI Solar Co Ltd shall not be held responsible fo...

Страница 5: ...liar with the safety specification about the electrical system 3 Be familiar with the local requirements rules and regulations 4 Understand the composition and working principles of the grid tied PV s...

Страница 6: ...itch Inverter AC Switch Electricity Meter Utility Grid FIG 3 1 PV Power System Diagram 3 2 Appearance Front view and bottom view A B C DE F GH A C B F E D GH C B I F E D G H CSI 3K S22002 E CSI 3 68 5...

Страница 7: ...00 LED Indicators Normal Waiting Steady Green Blinking Green No DC Input Off Error Steady Red More details please refer to the user manual Scan the QR code 624300XXXX FIG 3 3 Inverter Nameplate for re...

Страница 8: ...rter s weight for a long period time Please check the inverter s weight in the product specification of ANNEX B 3 The inverter is protected to IP65 can be installed indoors and outdoors 4 The humidity...

Страница 9: ...litate heat dissipation and to ensure that no moisture can penetrate the product 15 FIG 6 5 Installation Angle Requirements 13 Do not install the inverter outdoors in salt sulfur or other corrosive ar...

Страница 10: ...lling Positions 2 Drill expansion anchors into the corresponding four holes and then secure the bracket by using screws as per FIG 6 7 FIG 6 8 FIG 6 7 Install Expansion Anchors FIG 6 8 Fix Wall mounti...

Страница 11: ...pplied 7 3 Meter CT Connection Optional The inverter has integrated export limitation functionality To use this function a power meter or a CT must be installed For installation and operation methods...

Страница 12: ...d AC circuit breaker specifications are as follows Inverter type AC circuit breaker specifications CSI 3K S22002 E 25 A CSI 3 68K S22002 E 25 A CSI 5K S22002 E 32 A Recommend maximum AC cable length I...

Страница 13: ...0 8N m PE L N L N PE A A A A DEVALAN type Torque 1 4N m L N PE B B B B N PE L FIG 7 5 AC Terminal Positions 3 Push the threaded sleeve into the plug screw the press nut tightly EXCEEDCONN type DEVALAN...

Страница 14: ...value of the inverter Note Consider temperature coefficient of the PV modules Check the inverter specification in section ANNEX B 7 6 2 Wiring Negative Coupler Contactor Pin Positive Coupler Contacto...

Страница 15: ...bottom terminal of the inverter until one sound click audibly The locked DC connectors can only be disconnected with special tool FIG 7 14 Illustration of DC Ports 7 6 3 Connecting PV array DC input D...

Страница 16: ...narios to operate as per FIG 8 2 1 Standard Mode Connect to internet and operate the inverter through CSI cloud web or App 2 Local Mode Connect and operate the inverter locally without internet Soluti...

Страница 17: ...cally when the DC input voltage meets the performance requirement of the utility grid Normally there will be three statuses during the operation refer to the LED indications 1 Waiting Conditions The i...

Страница 18: ...ndertaken in the absence of proper tools test equipment or the more recent revision of the manual with has been clearly and thoroughly understood Items Methods Period System clean Check the temperatur...

Страница 19: ...ect the AC connector turn on DC Switch inverter will restore the grid connection automatically 4 If error message still exists contact Customer service F 107 DC component over range 1 Restart inverter...

Страница 20: ...h sides of the inverter 4 Remove the inverter from the bracket Note Before performing any work ensure that you are familiar with this document 12 2 Packing Inverter If possible use the original packag...

Страница 21: ...DC direct current LED light emitting diode MPPT maximum power point tracking PC personal computer PE protecting earthing PV photovoltaic RCD residual current protective device RCM residual current ope...

Страница 22: ...8 97 5 98 0 European Efficiency 97 1 96 8 97 5 MPPT Efficiency 99 9 99 5 99 9 Safety Protection DC Switch Integrated Anti Islanding Protection Integrated DC Reverse Protection Integrated Insulation Mo...

Страница 23: ...ngsu China 215129 Sales Inquiries Email sales emea csisolar com Customer Support Email service emea csisolar com This manual is subject to change without prior notification Copyright is reserved Dupli...

Страница 24: ...ANNEX C CE RoHS Declaration...

Страница 25: ......

Страница 26: ...ANNEX D REACH Declaration...

Страница 27: ......

Страница 28: ......

Отзывы: