Maximum Load: 
Uplift load ≤ 2400 Pa 
Downforce load ≤ 5400 Pa 

Compatible module types

 

CS6PH-P, CS6PH-M, CS6AH-P and CS6AH-M 

Uplift load ≤ 2400 Pa 
Downforce load ≤4000 Pa 
 

Compatible module types

 

CS6PH-P, CS6PH-M, CS6AH-P and CS6AH-M   
 

 
 
 

Bolting on the long frame side using four middle 
mounting holes. 
Mounting rails run perpendicularly to the long 
frame side. 

 

 
Maximum Load: 
Uplift load ≤ 2400 Pa 
Downforce load ≤ 5400 Pa 
Compatible module types

 

CS6XH-P and CS6XH-M 

Bolting on the long frame side using four middle 
mounting holes.   
Mounting rails run parallel to the long frame side. 

 

Maximum Load: 
Uplift load ≤ 2400 Pa 
Downforce load ≤5400 Pa 
Compatible module types: 
CS6XH-P and CS6XH-M 

 
 
 

7.0    MAINTENANCE 

 

Do not make modifications to any component of the PV module (diode, junction box, plug connectors or 
others).       

 

Regular  maintenance  is  required  to  keep  modules  clear  of  snow,  bird  droppings,  seeds,  pollen,  leaves, 
branches, dirt spots, and dust.     

 

Modules with sufficient tilt (at least 15°), generally may not require cleaning (rain will have a self-cleaning 
effect). If the module has become soiled, wash with water and a non-abrasive cleaning implement (sponge) 
during the cool part of the day. Do not scrape or rub dry dirt away, as this may cause micro scratches. 

 

Snow should be removed using a soft brush. 

 

Periodically inspect the system to check the integrity of all wiring and supports. 

 

To protect against electric shock or injury, electrical or mechanical inspections and maintenance should be 

Содержание CS5AH-180M

Страница 1: ...ABILITY 1 2 0 SAFETY PRECAUTIONS 1 3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 2 4 0 UNPACKING AND STORAGE 4 5 0 MODULE INSTALLATION 4 5 1 MODULE WIRING 7 5 2 GROUNDING 8 6 0 MOUNTING INSTRUCTIONS 8 6 1...

Страница 2: ...nguage versions of this document the English version shall prevail Please refer to our product lists and documents published on our website at http www canadiansolar com as these lists are updated on...

Страница 3: ...e junction box cover closed at all times Do not disassemble a module or remove any module part Do not artificially concentrate sunlight on a module Do not connect or disconnect modules when current fr...

Страница 4: ...circuit voltage can be calculated using the following formula CVoc 1 Voc 25 T T is the lowest expected ambient temperature at the system installation site Voc C is the voltage temperature coefficient...

Страница 5: ...n to avoid module backsheets being damaged by sharp objects as scratches may directly affect product safety Do not leave modules unsupported or unsecured Do not change the wiring of bypass diodes Keep...

Страница 6: ...Temperature and humidity Please consult the Canadian Solar Inc technical support department for more information on the use of modules in special climates such as an altitude greater than 2000m Do no...

Страница 7: ...en designing the system The recommended maximum series fuse rating is stated in a table in the Annex C Modules should be safely fixed to bear all expected loads including wind and snow loads A minimum...

Страница 8: ...erproof when unmated When installing modules connector should be connected to each other as soon as possible or appropriate measures like using connector endcaps should be taken to avoid moisture and...

Страница 9: ...less steel unless otherwise specified Canadian Solar Inc does not provide grounding hardware One grounding method is recommended for Canadian Solar Inc classic modules as described below For alternati...

Страница 10: ...modules can be installed in either landscape or portrait orientations Refer to the detailed instructions for further guidance Please note that in areas with heavy snowfall 2400 Pa further countermeas...

Страница 11: ...de using four standard mounting holes Mounting rails run perpendicularly to the long frame side An additional support bar should be placed below the module as shown below Maximum Load Uplift load 2400...

Страница 12: ...oad 2400 Pa Downforce load 5400 Pa Compatible module types CS6XH P and CS6XH M 7 0 MAINTENANCE Do not make modifications to any component of the PV module diode junction box plug connectors or others...

Страница 13: ...nadiansolar com Rev IM GN CM EN 1 0 Copyright October 2020 Canadian Solar Inc 12 performed by qualified personnel only Please refer to Annex D Module Cleaning Guide for additional information on this...

Страница 14: ...as described below All the requirements of the standard module installation manual and specific tracker detailed installation instructions should apply Tracker 1P Clamping method Overlap support lengt...

Страница 15: ...10 41 6 5 07 49 4 5 38 15 CS5PH 235P 235 50 8 4 63 62 6 4 93 15 1602 1061 40 1602 1061 35 20 30 CS5PH 240P 240 51 0 4 71 62 8 5 00 15 CS5PH 245P 245 51 4 4 79 63 0 5 07 15 CS5PH 250P 250 51 4 4 87 63...

Страница 16: ...290 30 6 9 48 36 9 10 08 20 CS6PH 295M 295 30 9 9 55 37 1 10 14 20 CS6PH 300M 300 31 2 9 62 37 3 10 19 20 CS6PH 305M 305 31 5 9 69 37 5 10 25 20 CS6PH 310M 310 31 8 9 75 37 7 10 31 20 CS6XH 345M 345...

Страница 17: ...t in injury Ensure that the array has been disconnected to other active components such as inverter or combiner boxes before starting with the cleaning Wear suitable protection clothes insulated glove...