ECUmaster
Please activate the Can Switchboard V3 in the DSS. As always, the Can Bus speed is identical in ECU
and MCE.
With the Can Bus Data Format version 3, the EMU supports more analog inputs via Can Bus. Up to 8
analogue inputs can be sent to the control unit. To do this, please activate the ECM switch board in
the EMU software under "CAN, Serial". To do this, please tick the box and select "CSB V3 0x640" as
the CSB type. Furthermore, the checkmarks for the individual AINs must be set. As usual, all changes
are written to the ECU using the "make permanent" button.
5.3
MaxxECU and others
Please enable the standard protocol in the DSS. As always, the Can Bus speed is identical in ECU and
MCE.
All further steps to use the MCE18 with your MaxxECU can be found in the MaxxECU Help:
https://www.maxxecu.com/webhelp/can-external_devices-canchecked_mce18.html