19
until the fault is corrected and will automatically return to
normal operating state.
SERVICE PARTS
The Valiant FT Series II Control is not field repairable. Any
modification or repairs will invalidate the warranty and may
create hazardous conditions that result in property damage,
personal injury, fire, explosion and/or toxic gases. A faulty
direct spark igniter MUST be replaced with a new factory
part. DO NOT use general purpose field replacement parts.
Each appliance has one control board, one direct spark
igniter and one flame sensor. A list of recommended spare
parts is illustrated in parts breakdown in this manual.
VALIANT FT SERIES II BOILER CONTROLS
The appliance is provided with an end-user HMI
touchscreen at the front and an operator interface digital
display inside. The HMI touchscreen provides access to
general boiler and display adjustments to the central
heating, domestic hot water, and lead lag setpoints. The
operator interface inside the boiler allows for changes to
additional boiler parameters for ease of startup and
serviceability.
PART 6 CONTROL SETTINGS
Parameter
Description
Demand
Central Heating (ARH)
Domestic Hot Water (ARW)
Lead Lag
Burner State
Current Status of Valiant FT Series II
Firing Rate
Target Firing Rate
Inlet
Inlet Water Temperature [°F]
Outlet
Outlet Water Temperature [°F]
Stack
Stack Temperature [°F]
DHW
DHW Temperature [°F], if equipped
Header
Header Temperature [°F], if equipped
Outdoor
Outdoor Temperature [°F], if equipped
Button
Description
Configure
Access Valiant Series II parameters (CH
Parameters, DHW Parameters, Outdoor
Reset, Pump Configuration etc.)
Operation
Details of Boiler Operation (Set point, Firing
Rate, Pump Status, Safety Circuit)
Diagnostics
Manual Firing Rate, Analog/Digital Status
Details
History, Pump Status, Outlet Temperature
Sequence of Operation
Flow Switch
: Flow Switch, Water Pressure Switch (12
PSIG), Low Water Cut Off (if equipped)
Gas Pressure Switch
: Low Gas Pressure Switch (4.5”-5.5”
w.c., N/O), High Gas Pressure Switch (14” w.c, N/C)
Interrupted Air Switch
: Air Proving Switch (N/O)
Pump B: Valiant
Pump
Содержание Valiant-FT II Series
Страница 2: ...99 0419 Rev 00...
Страница 40: ...36 PART 9 PIPING DIAGRAMS Figure 40 Single Boiler Hydronic Heating Zoned Piping...
Страница 41: ...37 Figure 41 Multiple Boiler Hydronic Heating Zoned Piping...
Страница 42: ...38 Figure 42 Single Boiler with DHW Tank Hydronic Heating Zoned Piping...
Страница 43: ...39 PART 10 PARTS LIST...
Страница 44: ...40...
Страница 45: ...41...
Страница 46: ...42...
Страница 47: ...43...
Страница 48: ...44...
Страница 49: ...45...
Страница 50: ...46...
Страница 51: ...47...
Страница 52: ...48...
Страница 53: ...49...
Страница 54: ...50...
Страница 60: ...56 PART 11 TUBING DIAGRAM...
Страница 61: ...57 PART 12 WIRING DIAGRAM...
Страница 62: ...58...
Страница 63: ...59...