3.6. Launch at destination / monitored place
When using the 230V network, the iCAM-Mobile power plug should be plugged into a
socket adapted to the conditions of use, i.e. an external hermetic socket or a socket with
a plug closed in another hermetic housing / box.
When using an alternative power source, the power cables must be routed through the
glands that are accessible to the user,
and then connect the plug to the EDG connector (+ - 12-24V DC car power supply), pay-
ing attention to the correct polarity.
WARNING
The time it takes to start the device at low temperatures can be extended by
several minutes. This is caused by the heater and thermostat. The device is
ready when the green LED STATUS NVR lights up.
After turning the key in the ignition switch to the „I” position (in the version with remote
control you should additionally press the ON button on the remote control near the devi-
ce) two light on the external panel should light up (
STATUS NVR, MAIN POWER
). iCAM-
MobileHD will start recording video and full remote access to the device will be possible.
WARNING
After starting the device, remove the key from the ignition, leaving it in position
"1" to prevent the system from being turned off by third parties.