background image

If the WPA data encryption method is selected, a network key is required, the same for 

all the CDS-5IP mini units. The user can select the encryption key type in the Data 

Encryption menu:

 

64-bit WEP: consists of no more than 10 hexadecimal characters. 

           128-bit WEP: consists of no more than 26 hexadecimal characters. 

9. The list of available frequencies (for the default channel width of 40 MHz)

Use the respective channels according to their intended purpose:

Selecting other frequencies depends on legal regulations applicable in the coun-

try of use. If not sure what regulations are applicable in the country of use, con-

sult with the CDS-5IP mini module seller.

indoor – only inside buildings,

outdoor – only outside buildings.

Adjustment

Range (intended use)

ETSI (European Union)

5,15 ~ 5,25 GHz

indoor

5,25 ~ 5,35 GHz

indoor

5,50 ~ 5,70 GHz

outdoor

36
44
52
60
100
108
116
124
136

5180
5220
5260
5300
5500
5540
5580
5620
5680

 

Channel frequency

Channel number

16

EU

EU

POLISH

MARK

POLISH

MARK

CDS-6IPECO User’s manual

Содержание CDS-6IPeco

Страница 1: ...External wireless transmission system of video and audio for IP cameras HD and UHD in the band 5 1 5 8 GHz User s manual www camsat com www camsat com ...

Страница 2: ...s of this manual comprise proprietary information of CAMSAT and are intended only for use by purchasers of the equipment described herein In order to copy or use any part of this manual for purposes other than the application or maintenance of the described equipment it is required that the customer should first obtain a written consent from CAMSAT 1 EU EU POLISH MARK POLISH MARK CDS 6IPECO User s ...

Страница 3: ...link name 6 6 Transmission distance 6 7 Wireless transmission testing 6 8 Password changing 7 Link testing with PING command 15 8 Radio transmission security 15 9 The list of available frequencies for the default channel width of 40 MHz 16 10 Table with technical parameters 17 Trouble solving 18 Appendix A 18 Warranty general conditions 19 Used equipment storage 20 Declaration of conformity 21 3 5...

Страница 4: ...n selected countries The device is suitable for use in the European Union This device has been designed and manufactured with the utmost care for the safety of its installers and users For safety reasons observe all the guidelines in this manual and peripheral devices manuals such as the PC or IP camera Before installing the device carefully read the entire instruction manual Ensure safe working c...

Страница 5: ...ferred to a room where the temperature is higher than where it has previously been kept water vapour may condensate inside its casing which will prevent its proper use Wait until the condensed water evaporates R TTE declaration of conformity Distances and interferences The transmission distance may vary depending on the frequency environment radio waves buildings weather conditions etc 1 When the ...

Страница 6: ... connector it works both in the point to point and point to multipoint topologies output power 27 dBm operating band 5 GHz transmission secured with a 64 128 bit code one receiver module can receive signals from four transmitters cameras camera and module may be fed from one PoE 12 24 V power supply LED radio signal level indicator built in dual MIMO 5 Ghz 2 x 14 dBi antenna LoS coverage 2 km oute...

Страница 7: ...6IPeco module set the IP address of the computer on the same subnet as the device CDS 6IPeco default address 192 168 1 1 then open a Web browser preferably Internet Explorer and enter the IP address of the module Login menu will appear on the screen Scheme 1 Power and connect CDS 6IPeco unit to the computer In the above screen enter your login information default Username camsat Password camsat th...

Страница 8: ...hernet cables The pole must be earthed unconditionally Failure to observe these guidelines may result in damaging the equipment during lightning strikes This type of damage is not covered by the warranty Wireless settings Setting mode Master receiver Slave transmitter encoding settings of transmission WAN Settings mode settings of the wireless link eg Video Bridge Wireless Advanced Settings the co...

Страница 9: ...eled POE in the supplied PoE power supply B To the second connector in CDS 6IPeco module A marked as LAN PoE 24V connect the cable network the computer or IP camera C 8 EU EU POLISH MARK POLISH MARK CDS 6IPECO User s manual 5 Connection to the system Option 1 Power CDS 6IPeco module by PoE connect the camera to the module Scheme 2 Option 1 devices connection Scheme 3 Option 2 devices connection Fo...

Страница 10: ...ard network cable with RJ45 connector tip to PoE OUT 48V D The second camera F must be connected to the LAN connector on the CDS 6IPeco module A Option 4 Power CDS 6IPeco Module and camera using the power converter from PoE48V to PoE24V Power socket 12 24V DC LAN LAN A B C D Power Socket 48V DC PoE 48V DC PoE 24V LAN PoE 48V LAN LAN 1 2 3 PoE 4 POWER SUPPLY PoE 48V POWER INPUT 48V DC PoE IN 48V Po...

Страница 11: ...er In the address bar type the IP address of the CDS 6IPeco default 192 168 1 1 You should see the following login screen If the browser returns an error go back to step 1 and make sure of the correctness of what you type an IP address c To log on to the network interface the user must enter a user name and password camsat camsat be included in the management interface of CDS 6IPeco module a CAMER...

Страница 12: ...an automatically reset itself and then you will need to log in again Modules CDS 6IPeco allow you to scan the ether for use in the vicinity of the frequen cy When setting the operating channel it is a very useful tool It shows which chan nels to avoid and which ones are free and can be used to transmit wireless signals from IP cameras The use of a channel that is already occupied by other transmis...

Страница 13: ...S button to begin scanning automatically After a while the list of the frequencies used in the area will be displayed together with the strengths of their signals The signals below 85 are considered as noises Such frequencies and channels which are not on the list may be used for the wireless Video transmission Do not use AUTO channel settings Be sure to select the channel number on a permanent ac...

Страница 14: ...nced Settings change the Distance parameter by entering the actual distance in kilometers a The last step is to check the correctness of transmission between devices To check the information about connected CDS 6IPeco devices such as the MAC address signal strength connection time IP address etc go to the Link Status menu The basic information about the wireless connection will appear in the Wirel...

Страница 15: ...he possibility to log on to the device by unauthorized per sons In the New Password field enter the new password and confirm it in the Con firm Password field Confirm the change with Save Changes button a 6 8 Password changing Settings recommended 14 EU EU POLISH MARK POLISH MARK CDS 6IPECO User s manual ...

Страница 16: ...ly configured you can execute the command PING with the address of each device in the system CDS 6IPeco IP cameras routers recorders 8 Radio transmission security The CDS 6IPeco devices have the option of securing video transmission with an encryption key or such algorithms as WPA PSK and WPA PSK2 To secure the transmission select the CAMERA CONNECTION SETTINGS Wireless Settings Z rozwijalnego menu...

Страница 17: ...spective channels according to their intended purpose Selecting other frequencies depends on legal regulations applicable in the coun try of use If not sure what regulations are applicable in the country of use con sult with the CDS 5IP mini module seller indoor only inside buildings outdoor only outside buildings Adjustment Range intended use ETSI European Union 5 15 5 25 GHz indoor 5 25 5 35 GHz...

Страница 18: ...ission Power supply Power consumption 12 Watt Power supply LAN LAN ports Casing dimensions Weight Casing ingress protection Storage temperature Humidity Environmental directives Warranty IP55 20 70 C 40 85 C 24 months IEEE 802 11a 27dBm 6 24 Mbps IEEE 802 11n 27dBm MCS 0 3 IEEE 802 11a IEEE 802 11an 86dBm HT20 MCS0 83dBm HT40 MCS0 ETSI EU 5180 5300MHz 5500 5660MHz OFDM BPSK QPSK CCK DQPSK DBPSK 1 ...

Страница 19: ... to Control Panel Network and Internet Network Connections Then select the current network adapter which is connected to the module CDS 6IPeco Click on Internet Protocol Version 4 TCP IPv4 on the list and then click Properties In an open window you can enter a new IP address of the computer or by clicking on the Advanced button Add you can enter another computer s IP address not to change the curr...

Страница 20: ...will be carried out in the shortest possible amount of time not exceeding 14 days counting from the moment of accepting the device for servicing If parts need to be imported the repair deadline may be extended After the repairs have been car ried out the warranty period will be extended by the repair time resulting from device repair or malfunction 7 The warrantor may refuse to carry out warranty ...

Страница 21: ...ste disposal is subject to penalties provided for in the appropriate regulations The mark presented to the left informs that this electrical or electronic device after its use has ended cannot be thrown together with household refuse The device should be delivered to a specialised collection point Detailed information about the closest collection point is available from local authorities VII Devic...

Страница 22: ...21 VIII Declaration of conformity ...

Страница 23: ...ry country It is your responsibility to be adequate settings of the complying with the applicable laws in the country or region Producer CAMSAT Gralak Przemysław Ogrodowa 2a 86 050 Solec Kujawski Poland Offer and information www camsat com Service serwis camsat com pl Technical support Mon Fr 8 00 AM 4 00 PM tel 48 52 387 10 97 EU EU POLISH MARK POLISH MARK CDS 6IPECO User s manual Warning about t...

Отзывы: