Appendix D. Extended ASCII Command Set
D-6
D.3.1 Set GOES DCP Platform ID
Syntax:
NESID=xxxxxxxx
Access level: USER
TX321 state: Disabled
Sets the transmitter GOES DCP Platform ID to the hex value xxxxxxxx. Valid
range is even hex numbers from 2 to 0xfffffffe.
D.3.2 Set Self-Timed Transmission Channel Number
Syntax:
TCH=ccc
Access level: USER
TX321 state: Disabled
This command sets the channel number (
ccc
) for timed transmissions.
ccc
is
the channel number and has a valid range of 0 – 266 for bit rates of 100 and
300 bps and a range of 0 – 133 for a bit rate of 1200 bps.
For 100 bps operation on channels 201 – 266, the transmitter will be
configured for international operation. Specifically, the 31-bit international End
of Transmission (EOT) will be used (0x63CADD04) in place of the ASCII
EOT, and the preamble will be forced to Long.
Setting the channel number to 0 will disable timed transmissions.
D.3.3 Set Self-Timed Transmission Bit Rate
Syntax:
TBR=bbbb
Access level: USER
TX321 state: Disabled
This command sets the timed transmission bit rate where
bbbb
is the bit rate
parameter and has valid values of 100, 300 and 1200 bps.
D.3.4 Set Self-Timed Transmission Interval
Syntax:
TIN=dd:hh:mm:ss
Access level: USER
TX321 state: Disabled
Set interval between timed transmissions to days, hours, minutes, seconds
specified in dd:hh:mm:ss. Valid range is 00:00:05:00 to 30:23:59:59.
Содержание TX321
Страница 1: ...TX321 Transmitter Revision 5 19 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 46: ......
Страница 48: ......
Страница 56: ......
Страница 82: ......
Страница 84: ...AppendixE Meteosat F 2 FIGURE F 2 DCPRS and CGMS certificate ...
Страница 85: ...AppendixE Meteosat F 3 FIGURE F 3 EUMETSAT certificate ...