background image

Assistance

Products may not be returned without prior authorization. 

Products shipped to Campbell Scientific require a Returned Materials Authorization (RMA) or 
Repair Reference number and must be clean and uncontaminated by harmful substances, such 
as hazardous materials, chemicals, insects, and pests. Please complete the required forms prior to 
shipping equipment.

Campbell Scientific regional offices handle repairs for customers within their territories. Please 
see the back page for the Global Sales and Support Network or visit 

www.campbellsci.com/contact

 

 to determine which Campbell Scientific office serves your 

country.

To obtain a Returned Materials Authorization or Repair Reference number, contact your 
CAMPBELL SCIENTIFIC regional office.  Please write the issued number clearly on the outside of 
the shipping container and ship as directed. 

For all returns, the customer must provide a “Statement of Product Cleanliness and 
Decontamination” or “Declaration of Hazardous Material and Decontamination” form and 
comply with the requirements specified in it. The form is available from your CAMPBELL 
SCIENTIFIC regional office. Campbell Scientific is unable to process any returns until we receive 
this statement. If the statement is not received within three days of product receipt or is 
incomplete, the product will be returned to the customer at the customer’s expense. Campbell 
Scientific reserves the right to refuse service on products that were exposed to contaminants that 
may cause health or safety concerns for our employees.

Содержание TEMPERATURE PROBE 109SS

Страница 1: ...Revision 05 2021 Copyright 1983 2021 Campbell Scientific Inc...

Страница 2: ...oil temperature installation 8 8 Operation 8 8 1 Sensor schematic 8 8 2 Measurement and output linearization 8 8 3 Electrically noisy environments 9 8 4 Long cable lengths 9 9 Troubleshooting and main...

Страница 3: ...ning when tested according to U L 94 H B and passes FMVSS302 However local fire codes may preclude its use inside buildings 3 Initial inspection Check the packaging and contents of the shipment If dam...

Страница 4: ...ng procedure also describes programming with Short Cut 1 Open Short Cut and click Create New Program 2 Double click the data logger model 3 In the Available Sensors and Devices box type 109 or find th...

Страница 5: ...wired to the data logger Click OK after wiring the sensor 5 Repeat steps three and four for other sensors being measured Click Next 6 In Output Setup type the scan rate Data Output Storage Intervals...

Страница 6: ...s a rugged probe that accurately measures soil or water temperature in a variety of applications The sensor consists of a thermistor encased in a stainless steel sheath This design protects the thermi...

Страница 7: ...ble length 305 m 1000 ft Accuracy1 Worst case 0 60 C 40 to 70 C 0 49 C 20 to 70 C Maximum submergence 45 m 150 ft 63 psi Interchangeability error 0 60 C at 40 C 0 38 C at 0 C 0 10 C at 25 C 0 30 C at...

Страница 8: ...Data logger programming p 6 Short Cut does this work for you See QuickStart p 1 for a Short Cut tutorial 7 1 Wiring to data logger Table 7 1 Wire color function and data logger connection Wire color...

Страница 9: ...vided in Measurement and output linearization p 8 7 2 1 Therm109 instruction The Therm109 measurement instruction programs CRBasic data loggers to measure this sensor It applies a precise excitation v...

Страница 10: ...ffect of solar heating of the above ground cable on the temperature measurement Placement of the cable inside a rugged conduit may be necessary for long cable runs especially in locations subject to d...

Страница 11: ...ficients provided by Measurement Specialties 8 3 Electrically noisy environments EMF noise emanating from the ac mains power grid can be a significant source of measurement error 60 Hz noise is common...

Страница 12: ...A and completion of the Declaration of Hazardous Material and Decontamination form Refer to the Assistance page at the back of this manual for more information 9 1 Troubleshooting Symptom Temperature...

Страница 13: ...n If needed an estimate of the interchangeability error for 0 to 50 C that can be used as the Offset parameter of the Therm109 instruction can be determined with a 1 point or 2 point calibration Calib...

Страница 14: ...ted for additional refinement NOTE Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into the new CRB...

Страница 15: ...Wire Data logger Color Function Terminal Black Voltage excitation input VX1 EX1 Red Analog voltage output SE1 Purple Bridge resistor ground Ground Symbol Clear Shield Ground Symbol Declare the variabl...

Страница 16: ...40 336103 2 40 00 39 314558 39 00 38 294529 1 38 00 37 275900 8 37 00 36 258567 36 00 35 242430 2 35 00 34 227400 9 34 00 33 213396 6 33 00 32 200341 4 32 00 31 188165 5 31 00 30 176804 8 30 00 29 166...

Страница 17: ...17 81641 4 17 00 16 77138 6 16 00 15 72911 1 15 00 14 68940 4 14 00 13 65209 7 13 00 12 61702 9 12 00 11 58405 5 11 00 10 55303 9 10 00 9 52385 2 9 00 8 49637 8 8 00 7 47050 6 7 00 6 44613 4 6 00 5 4...

Страница 18: ...00 10 19903 2 10 00 11 18973 3 11 00 12 18092 2 12 00 13 17256 9 13 00 14 16464 9 14 00 15 15713 7 15 00 16 15000 9 16 00 17 14324 5 17 00 18 13682 3 18 00 19 13072 6 19 00 20 12493 3 20 00 21 11943...

Страница 19: ...5 6530 3 35 00 36 6266 2 36 00 37 6014 3 37 00 38 5773 8 38 00 39 5544 2 39 00 40 5325 40 00 41 5115 6 41 00 42 4915 6 42 00 43 4724 4 43 00 44 4541 7 44 00 45 4367 45 00 46 4200 46 00 47 4040 2 47 00...

Страница 20: ...3 9 58 00 59 2578 6 59 00 60 2487 1 60 00 61 2399 4 61 00 62 2315 2 62 00 63 2234 4 63 00 64 2156 8 64 00 65 2082 3 65 00 66 2010 8 66 00 67 1942 1 67 00 68 1876 68 00 69 1812 6 69 00 70 1751 6 70 00...

Страница 21: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 22: ...ion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the...

Страница 23: ...rohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l Y...

Страница 24: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...