6. Specifications
Features:
l
Individual measurement of four net radiation components
l
SDI-12 output, eliminating the need for multiple analog channels to measure the individual
components of net radiation
l
Complete package that includes net radiometer, mounting rod, cable for data logger inter-
face, and carrying case
l
Compatible with Campbell Scientific CRBasic data loggers: CR300 series, CR6, CR200(X)
series, CR800 series, CR1000X, CR1000, CR3000, and CR5000
Pyranometer spectral response:
385 to 2105 nm (upward-looking)
295 to 2685 nm (downward-looking)
Pyranometer sensitivity range:
0.057 mV per W/m
2
(upward-looking)
0.15 mV per W/m
2
(downward-looking)
Pyranometer expected output range: 0 to 114 mV (upward-looking)
0 to 300 mV (downward-looking)
Pyrgeometer spectral response:
5,000 to 30,000 nm
Pyrgeometer sensitivity range:
0.12 mV per W/m
2
Pyrgeometer expected output range: –24 to 24 mV
Operating temperature range:
–50 to 80 °C
Relative humidity:
0 to 100%
Response time:
1 s (SDI-12 data transfer rate; detector response times are
0.5 s)
Heater current drain (at 12 Vdc):
63 mA (heaters on; communication enabled)
1.5 mA (heaters off; communication enabled)
0.6 mA (heaters off; communication disabled)
Dimensions:
11.6 x 4.5 x 6.6 cm (4.6 x 1.8 x 2.6 in)
Weight:
320 g (11.29 oz) with mounting rod and 5 m (16.4 ft) cable
SN500SS Net Radiometer
6