Appendix D. Verizon Wireless
and AT&T

NOTE:
Campbell Scientific can provide Verizon Wireless or AT&T service. This is the simplest way to
set up your module on the Verizon Wireless or AT&T network. See

Campbell Scientific

cellular data service

(p. 3).

D.1 Verizon Wireless

What you need:

l

Verizon Wireless 4G LTE CAT-1 coverage at the data logger site. For a coverage map, refer
to:

www.verizonwireless.com/landingpages/better-matters/#maps

l

Verizon Wireless 4G LTE private dynamic IP account in conjunction with Campbell
Scientific Konect PakBus Router Service. (A Verizon Wireless 4G LTE static unrestricted IP
account can also be used. However, Verizon generally requires new users to have 50 lines
of service to obtain the static unrestricted IP account. Also, there is generally a $500 one-
time-per-customer charge to activate static IP on the account.)

To set up an account, you will need the IMEI number of the module. The IMEI number is listed on
a label on the module. To set up an account with Verizon Wireless, call:

800-526-3178 for Business Sales
800-256-4646 for Personal Sales

Verizon Wireless will provide a SIM (Subscriber Identity Module) card for each module. The Mini-
SIM (2FF) card must be installed inside of the module as described in

Install the SIM card

(p. 4).

In addition to the SIM card, you should receive:

l

10-digit MSISDN number (telephone number associated with the SIM, used for billing)

l

An APN (Access Point Name) for 4G LTE CAT-1 service. A common APN used for this
application is: VZWINTERNET. The user must program the APN into the module.

l

For static IP accounts only, an IP Address will be included.

RV50(X) Sierra Wireless AirLink® 4G LTE Cellular Modem

47

Содержание Sierra Wireless AirLink RV50

Страница 1: ...Revision 01 2020 Copyright 2016 2020 Campbell Scientific Inc...

Страница 2: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 3: ...ing address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and co...

Страница 4: ...work l Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers l Do not climb tripods or towers at any time and prohibit climbing...

Страница 5: ...ter private dynamic IP 10 5 1 1 Configure RV50 X 10 5 1 2 Enabling PPP mode 12 5 1 3 Set up LoggerNet 14 5 1 4 Test the connection 17 5 2 Modules using a public static IP 17 5 2 1 Configure RV50 X 17...

Страница 6: ...lt settings 37 8 6 Recovery mode 37 9 Attributions 38 Appendix A ACEManager and template files 39 Appendix B Controlling power to the RV50 X 43 Appendix C Using the RV50 X Ethernet port 45 Appendix D...

Страница 7: ...tudy l Safety p iii l Initial inspection p 2 l Pre installation p 3 l QuickStart p 8 The RV50 X module may be configured in one of two ways depending on the communications type and needs of the user A...

Страница 8: ...12V to control power to the RV50 X We strongly recommend changing the default RV50 X ACEmanager password to prevent unauthorized access and the potential of malware infection The password can be chan...

Страница 9: ...des more incoming communication functionality but is less secure and more vulnerable to unsolicited traffic NOTE A public static IP account must be used when the module is set up in serial server mode...

Страница 10: ...dy installed Proceed to Konect PakBus Router setup p 5 The RV50 X requires a Mini SIM 2FF a smartcard that securely stores the key identifying a mobile subscriber You should only need to install the S...

Страница 11: ...ommunication No other incoming communication is supported However all forms of outbound communication from the data logger are supported including but not limited to PakBus email and ftp Complete the...

Страница 12: ...nutes apart One email will contain a Passport ID and the other your Password If emails are not received check your email junk folder 4 3 2 Set up Konect PakBus Router 1 Sign in to www konectgds com us...

Страница 13: ...cellular enabled device and click Submit 3 The next screen shows the assigned DNS address and Port for the router An optional TCP Password may be entered for additional security and you must select a...

Страница 14: ...p cannot be edited 5 QuickStart The Provisioning Report received with your Cellular Data Service shows whether the module was configured with a private dynamic or public static IP address See the foll...

Страница 15: ...dress will have two stickers on the module One sticker will show the module phone number and data plan The second sticker will show the static IP address Campbell Scientific cellular modules configure...

Страница 16: ...ACEmanager to disable WAN Cellular Network Credentials RX Diversity 4 Connect the power cable leads to a power supply Wire Color Function Connect To Black Ground G White Enable On Off 12V or SW12V or...

Страница 17: ...er login screen should appear in your browser 8 Log in using User Name user and Password 12345 We strongly recommend changing the default password to prevent unauthorized access and the potential of m...

Страница 18: ...CR800 series CR5000 and GRANITE 6 9 10 2CR10X CR10X PB CR510 CR510 PB CR23X CR23X PB and CR200 X series data loggers 11 Reboot the RV50 X after successfully applying the configuration template You can...

Страница 19: ...s is generally RS 232 Change the Baud Rate to 115200 Fixed On the PPP tab select the Config Port Used where the modem is connected This is the same as was selected on the Com Ports Settings tab Set Mo...

Страница 20: ...Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup screen and select Standard view From the LoggerNet toolbar click Main Setup and config...

Страница 21: ...s and port number are input in the Internet IP Address field separated by a colon For example axanar konectgds com pppp where pppp is the port number 5 For PakBus data loggers leave the default settin...

Страница 22: ...oggers select the data logger in the Network Map and set the PakBus Address to match that of the data logger default address in the data logger is 1 If a PakBus Encryption Key was entered during data...

Страница 23: ...creen will come together and clock information from the data logger will be displayed in the Station Date Time field If the connection fails a Communications Failure message will be displayed 5 2 Modu...

Страница 24: ...o 10 minutes A successful connection is indicated by a solid green or solid amber Network LED NOTE If Campbell Scientific did not provision the RV50 X or it does not automatically connect to the netwo...

Страница 25: ...et server such as www campbellsci com 10 Click the Template button in the ACEmanager toolbar A template application window will appear Browse to and upload one of the configuration templates downloade...

Страница 26: ...ing power from the RV50 X 5 2 2 Enabling PPP mode Launch the Device Configuration Utility All tabs are within the Deployment category On the Datalogger tab make note of the data logger PakBus Address...

Страница 27: ...ork Map is configured from the LoggerNet Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup screen and select Standard view From the Logg...

Страница 28: ...d by a colon Preceding zeros are not entered in the Internet IP Address for example 070 218 074 247 is entered as 70 218 74 247 The default port number is 6785 5 For PakBus data loggers leave the defa...

Страница 29: ...to save the changes 5 2 4 Test the connection After the Network Map has been configured test the cellular connection by using the Connect screen as shown in the following image Click on the appropria...

Страница 30: ...s AirLink RV50 MC7355 radio module and RV50X MC7455 radio module cellular modules Cellular WAN l Network Technology 4G with automatic fallback to 3G and 2G RV50 only l See https s campbellsci com docu...

Страница 31: ...158 F l Storage Temperature 40 to 85 C 40 to 185 F l Humidity 90 60 C l Military Specification MIL STD 810G conformance to shock vibration thermal shock and humidity l IP64 rated ingress protection I...

Страница 32: ...ace connects the module to any data logger with a CS I O port It must be configured using Device Configuration Utility Settings should be l CS I O Mode SDC Address 8 l CS I O ME Baud Rate 115 2k l RS...

Страница 33: ...antenna includes a mount U bolt assembly for attaching the antenna to a mast post or crossarm up to 3 8 cm 1 5 in in diameter o 8 dBd Yagi Wideband Antenna A higher gain antenna that should be aimed...

Страница 34: ...damage and so they will not be snagged or pulled on Avoid binding or sharp corners in the cable routing Bundle and tie off excess cable Make sure the cables are secured so their weight will not loosen...

Страница 35: ...acket Then use two of the included pan head Phillips screws to mount the bracket to the backplate 7 3 Wiring and connections This section explains how to connect the module for different communication...

Страница 36: ...RJ45 to DB9 Male DTE is used to connect the module to the CR6 or GRANITE 6 9 10 Ethernet connection An Ethernet cable is used to connect the module to the Ethernet port of the data logger NL1XX or NL...

Страница 37: ...o the mobile network This process typically takes 5 to 10 minutes A successful connection is indicated by a solid green or solid amber Network LED Controlling power to the RV50 X p 43 provides an exam...

Страница 38: ...wever they are highly recommended in order to get the most reliable connection especially in areas of low coverage Identical or very similar antennas should also be used for the best results For 4G ne...

Страница 39: ...up You will need to know how your RV50 X was configured either with a private dynamic or public static IP address The Provisioning Report received from Campbell Scientific or another cellular provider...

Страница 40: ...reboot the modem Flashing Red When you press the reset button flashing red indicates when to release the reset button to reset the modem to the factory default settings Flashing Amber When you press...

Страница 41: ...ware Configuration User Guide Admin chapter from the Sierra Wireless website Activity Flashing Green Traffic is being transmitted or received over the WAN interface Flashing Red Traffic is being trans...

Страница 42: ...I are dBm 70 is a stronger signal than 100 l 78 good l 78 to 93 fair l 94 to 102 poor l less than 103 inadequate Because the RSSI can vary due to multipath interference or other environmental effects...

Страница 43: ...fault settings l On the RV50 X press the Reset button for more than 5 seconds Release the button when the Power LED flashes red Once the LEDs resume their normal operating behavior the reset is comple...

Страница 44: ...ACEmanager Recovery screen l Wait 10 minutes If no action is taken within 10 minutes of the module entering Recovery mode for example if the Recovery screen has not been loaded by the web browser it a...

Страница 45: ...rnet port on the computer and that on the module Type http 192 168 13 31 9191 into a web browser Once the module is provisioned on the network it may be accessed over the air by typing http followed b...

Страница 46: ...les Template File Name Description RV50_115200 xml Default configuration with RS 232 at 115200 baud and Ethernet communication enabled 1 RV50_9600 xml Default configuration with RS 232 at 9600 baud an...

Страница 47: ...ettings under the Serial tab after the 115200 baud template file has been loaded Click on WAN Cellular for the following screen Enter the APN as shown in the screen above The example is for an APN I2G...

Страница 48: ...Click Logout to terminate communications with the module WARNING Unless you Apply the commands the changes made will not be saved in the module For most commands you must reboot the module for the ne...

Страница 49: ...ter in the CR1000 CR3000 or CR800 It is supported in all CR1000X CR6 and CR300 operating systems CRBasic Example 1 Turn RV50 X ON and OFF under data logger control CR300 Series Declare Variables and U...

Страница 50: ...eState True PPPOpen SW12 1 Else ModuleState False PPPClose SW12 0 EndIf Always turn OFF RV50 X if battery drops below 11 5 volts If BattV 11 5 Then Set RV50 X power to the state of ModuleState variabl...

Страница 51: ...everal milliamps as compared to the use of serial communications The following example can be used to communicate with a CR1000 NL121 via the RV50 X Ethernet port Port forwarding in the RV50 X must be...

Страница 52: ...e address used in the RV50 X port forwarding configured previously Once the RV50 X and the CR1000 have been configured and the RV50 X has been rebooted you can communicate with the CR1000 via LoggerNe...

Страница 53: ...icted IP account Also there is generally a 500 one time per customer charge to activate static IP on the account To set up an account you will need the IMEI number of the module The IMEI number is lis...

Страница 54: ...for M2M Setup Who to ask for Carlos Morales or Andy Tran An APN Access Point Name must be added onto the account to make the module accessible through the Internet For networks with fewer than 30 modu...

Страница 55: ...dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications to this device not expressly approv...

Страница 56: ...X displays the CE mark Changes or modifications to this device not expressly approved by Sierra Wireless could void the user s authority to operate this equipment This product is only to be installed...

Страница 57: ...E 5 RoHS compliance RV50 X Sierra Wireless AirLink 4G LTE Cellular Modem 51...

Страница 58: ...cennes France Phone 0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci...

Отзывы: