SDM-SIO4 User Guide
6-4
*Table 1 Program
01: 1.0 Execution Interval (seconds)
;test flag 1 – if not set tell the SDM-SIO4 to use filter string 100
1: If Flag/Port (P91)
1: 21 Do if Flag 1 is Low
2: 30 Then Do
;tell the SDM-SIO4 to use filter string 100
2: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 2054 Command
5: 9100 1st Parameters
6: 0 2nd Parameters
7: 0 Values per Rep
8: 0000 Loc [ _________ ]
9: 0 Mult
10: 0 Offset
;a minimum delay of 4ms is required by the above P113
3: Excitation with Delay (P22)
1: 1 Ex Channel
2: 0 Delay W/Ex (units = 0.01 sec)
3: 1 Delay After Ex (units = 0.01 sec)
4: 0 mV Excitation
;set flag 1 to instruct the SDM-SIO4 to use the filter once only
4: Do (P86)
1: 11 Set Flag 1 High
;end of filter setup
5: End (P95)
;poll SDM-SIO4 to see if data is available for the datalogger to collect
;the value from the poll is read into location 1
6: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 1 Command
5: 0 1st Parameters
6: 0 2nd Parameters
7: 1 Values per Rep
8: 1 Loc [ _________ ]
9: 1 Mult
10: 0 Offset