Assistance 

Products may not be returned without prior authorization. The following 

contact information is for US and international customers residing in countries 

served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs 

for customers within their territories. Please visit 

www.campbellsci.com

 to 

determine which Campbell Scientific company serves your country. 

To obtain a Returned Materials Authorization (RMA) number, contact 

CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000. Please write the 

issued RMA number clearly on the outside of the shipping container. Campbell 

Scientific’s shipping address is: 

CAMPBELL SCIENTIFIC, INC.

 

RMA#_____ 

815 West 1800 North 

Logan, Utah 84321-1784 

For all returns, the customer must fill out a “Statement of Product Cleanliness 

and Decontamination” form and comply with the requirements specified in it. 

The form is available from our website a

www.campbellsci.com/repair

completed form must be either emailed to 

[email protected]

 or faxed to 

(435) 227-9106. Campbell Scientific is unable to process any returns until we 

receive this form. If the form is not received within three days of product 

receipt or is incomplete, the product will be returned to the customer at the 

customer’s expense. Campbell Scientific reserves the right to refuse service on 

products that were exposed to contaminants that may cause health or safety 

concerns for our employees. 

 

 

Содержание HFP01

Страница 1: ...HFP01 Soil Heat Flux Plate Revision 1 20 Copyright 2002 2020 Campbell Scientific Inc...

Страница 2: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 3: ...ing address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and co...

Страница 4: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 5: ...spection 1 4 QuickStart 1 5 Overview 3 6 Specifications 4 7 Installation 4 7 1 Placement in Soil 5 7 2 Wiring 6 7 3 Programming 7 7 4 Soil Heat Flux and Storage 7 8 Maintenance 8 9 References 8 Append...

Страница 6: ...1 General characteristics of a heat flux sensor C 1 C 2 Deflection error C 2 Tables 7 1 Wire Color Function and Data Logger Connections 6 B 1 Wiring for CRBasic Example B 1 B 1 CRBasic Example B 1 Sa...

Страница 7: ...is rugged it should be handled as a precision scientific instrument 3 Initial Inspection Upon receipt of the HFP01 inspect the packaging and contents for damage File damage claims with the shipping co...

Страница 8: ...ate the sensor in the select Sensors Soil folder Double click HFP01 Soil Heat Flux Plate Type the sensitivity provided on the calibration sheet this value is sensor specific 4 Click the Wiring tab to...

Страница 9: ...splay in LoggerNet RTDAQ PC400 or PC200W to make sure it is making reasonable measurements 5 Overview The HFP01 Soil Heat Flux Plate uses a thermopile to measure temperature gradients across its plate...

Страница 10: ...s and principles of operation of heat flux sensors is shown in Appendix C General Theory of Heat Flux Sensors p C 1 Features Ideal for energy balance or Bowen ratio systems Compatible with Campbell Sc...

Страница 11: ...ors are installed in the undisturbed face of the hole Measure the sensor depths from the top of the hole With a small knife make a horizontal cut 16 cm below the surface into the undisturbed face of t...

Страница 12: ...ABLE 7 1 Wire Color Function and Data Logger Connections Wire Color Wire Function Data Logger Single Ended Measurement Data Logger Differential Measurement White Signal U configured for single ended a...

Страница 13: ...ded at www campbellsci com old manuals The HFP01 is measured using either a single ended VoltSE or differential VoltDiff instruction The differential measurement is recommended Syntax of the VoltDiff...

Страница 14: ...at capacity of dry soil is a reasonable value for most mineral soils Hanks and Ashcroft 1980 The storage term is then given by Eq 3 and the soil heat flux at the surface is given by Eq 4 S T C d t s s...

Страница 15: ...can now be edited for additional refinement Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into t...

Страница 16: ...ogger This data logger program measures two HFP01 Hukseflux soil heat flux sensors Constants Const HFP01_CAL_1 14 90 Unique multiplier for HFP01 1 1000 sensitivity 1000 67 1 Const HFP01_CAL_2 14 92 Un...

Страница 17: ...will enhance the output signal In FIGURE C 1 the joints of a copper constantan thermopile are alternatively placed on the hot and the cold side of the sensor The thermopile is embedded in a filling ma...

Страница 18: ...nd its environment for example 0 6 for a typical sensor and 0 03 for an insulating wall is about 40 FIGURE C 2 Deflection error The heat flux is deflected at the edges of the sensor As a result the he...

Страница 19: ...cennes France Phone 0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci...

Отзывы: