background image

 

 

 

CAMPBELL SCIENTIFIC COMPANIES 

 
 

 

Campbell Scientific, Inc. (CSI) 

815 West 1800 North 

Logan, Utah 84321 

UNITED STATES 

www.campbellsci.com

  

  

[email protected]

 

 

 
 

Campbell Scientific Africa Pty. Ltd. (CSAf) 

PO Box 2450 

Somerset West 7129 

SOUTH AFRICA 

www.csafrica.co.za

  

  

[email protected]

 

 

 
 

Campbell Scientific Southeast Asia Co., Ltd. 

877/22 Nirvana@Work, Rama 9 Road 

Suan Luang Subdistrict, Suan Luang District 

Bangkok 10250 

THAILAND 

www.campbellsci.asia

  

  

[email protected]

 

 
 
 

Campbell Scientific Australia Pty. Ltd. (CSA) 

PO Box 8108 

Garbutt Post Shop 

QLD 4814 AUSTRALIA 

www.campbellsci.com.au

  

  

[email protected]

 

 

 
 

Campbell Scientific do Brazil Ltda. (CSB) 

Rua Apinagés, nbr. 2018 - Perdizes 

CEP: 01258-00 São Paulo SP BRAZIL 

www.campbellsci.com.br

  

  

[email protected]

 

 

 
 

Campbell Scientific Canada Corp. (CSC) 

14532 – 131 Avenue NW 

Edmonton, Alberta T5L 4X4 

CANADA 

www.campbellsci.ca

  

  

[email protected]

 

 
 

Campbell Scientific Centro Caribe S.A. (CSCC) 

300N Cementerio, Edificio Breller 

Santo Domingo, Heredia 40305 

COSTA RICA 

www.campbellsci.cc

   

  

[email protected]

 

 

 
 

Campbell Scientific Ltd. (CSL) 

80 Hathern Road, Shepshed, Loughborough LE12 9GX 

UNITED KINGDOM 

www.campbellsci.co.uk

  

  

[email protected]

 

 

 
 

Campbell Scientific Ltd. (France) 

3 Avenue de la Division Leclerc 

92160 ANTONY 

FRANCE 

www.campbellsci.fr

  

  

[email protected]

 

 

 
 

Campbell Scientific Spain, S. L. 

Avda. Pompeu Fabra 7-9 

Local 1 - 08024 BARCELONA 

SPAIN 

www.campbellsci.es

  

  

[email protected]

 

 

 
 

Campbell Scientific Ltd. (Germany) 

Fahrenheitstrasse13, D-28359 Bremen 

GERMANY 

www.campbellsci.de

  

  

[email protected]

 

 

 
 

Campbell Scientific (Beijing) Co., Ltd. 

8B16, Floor 8 Tower B, Hanwei Plaza 

7 Guanghua Road, Chaoyang, Beijing 100004 

P.R. CHINA 

www.campbellsci.com

 

 

[email protected]

 

 

 
 
 
 
 
 
 
 

Please visit www.campbellsci.eu to obtain contact information for your local EU or International representative.

 

Содержание ENC 8/10

Страница 1: ...Enclosures ENC 8 10 ENC 10 12 ENC 12 14 ENC 14 16 ENC 16 18 and AM ENC ENCT Issued 6 9 17 Copyright 2000 2017 Campbell Scientific Ltd CSL 264 INSTALLATION MANUAL...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...t for recycling Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility Campbell Scientific...

Страница 6: ......

Страница 7: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Страница 8: ......

Страница 9: ...fitted with a power supply logger and multiplexer 2 7 1 An enclosure with the mast mounting option attaches to a tripod mast via u bolts 5 7 2 This exploded view shows the components of a mast mounti...

Страница 10: ...20 Terminal Strip installation A 2 A 3 15909 End Plate installation A 2 A 4 15909 Jumper installation A 3 A 5 DIN Rail bracket mounted onto an enclosure backplate A 3 A 6 An installed and wired 006706...

Страница 11: ...transducers and also prevents pressure build up in the enclosure in the event of a system failure when charging lead acid batteries A blanking plug is supplied which can replace the porous venting plu...

Страница 12: ...C 12 14 fitted with a power supply logger and multiplexer The AM ENC enclosure will accept up to two AM16 32s or one older now superseded AM416 multiplexer If installing the DIN Rail Terminal Kit 0102...

Страница 13: ...e cables should be filled with a suitable mastic compound such as Plumbers Mate or silicone rubber compound Do not use bath or tile sealant which gives off corrosive fumes that can damage circuit boar...

Страница 14: ...oisture adsorption or a container that prevents moisture from coming into contact with the regenerated desiccant Some care should be taken when re activating desiccant bags If heated in an oven which...

Страница 15: ...the bottom of the enclosure see Figures 7 1 7 2 and 7 3 Attach the enclosure to the mast as follows 1 Position the enclosure on the north side of the mast 2 Use the furnished 62 mm centre u bolts to s...

Страница 16: ...8 10 ENC 10 12 ENC 12 14 ENC 14 16 ENC 16 18 and AM ENC ENCT Enclosures 6 Figure 7 2 This exploded view shows the components of a mast mounting bracket Figure 7 3 An enclosure attached to a tripod ma...

Страница 17: ...ers adjust accordingly Attach the enclosure to a UT930 tower as follows 1 Remove the bolts and nuts connecting the bracket to the enclosure 2 Slide out the flange sections so that the distance between...

Страница 18: ...C 12 14 ENC 14 16 ENC 16 18 and AM ENC ENCT Enclosures 8 Flange Section Flange Section Figure 7 5 This exploded view shows the components of a tower mount bracket option Figure 7 6 An enclosure attach...

Страница 19: ...pped with the tripod and will need to be installed as shown in Figure 7 7 2 An ENC16 18 cannot be mounted to the leg base Attach the enclosure to the leg base as follows 1 Place the flange of the trip...

Страница 20: ...ENC 8 10 ENC 10 12 ENC 12 14 ENC 14 16 ENC 16 18 and AM ENC ENCT Enclosures 10 Notch Figure 7 8 An ENC 14 16 enclosure with a leg mount bracket Figure 7 9 The u bolt bracket...

Страница 21: ...rings with it additional problems such as adhesion It is important to note that any erosion is very superficial and has no effect on the physical characteristics electrical mechanical or chemical of t...

Страница 22: ...and AM ENC ENCT Enclosures 12 As of September 2009 all enclosures will be supplied with a special surface coating to reduce surface ageing No extra surface treating should be necessary unless the enc...

Страница 23: ...is mounted to an enclosure backplate using the kit s screws and grommets One 15920 terminal strip consists of three spring loaded guillotine terminals that provide connection points for individual wi...

Страница 24: ...Appendix A DIN rail terminal kits A 2 Figure A 2 15920 Terminal Strip installation Figure A 3 15907 End Plate installation 2 Insert the 15909 Jumpers in the terminal strips as shown in Figure A 4...

Страница 25: ...see Figure A 5 The 006706 includes three screws and three grommets Use the third screw and grommet to secure the 9 pin DIN Rail at its centre Figure A 5 DIN Rail bracket mounted onto an enclosure bac...

Страница 26: ...Appendix A DIN rail terminal kits A 4 Figure A 6 An installed and wired 006706 002 DIN Rail Terminal Kit Figure A 7 The 006706 002 DIN Rail Terminal Kit facilitates wiring of multiple sensors...

Страница 27: ......

Страница 28: ...W Edmonton Alberta T5L 4X4 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www c...

Отзывы: