CSAT3B Three-Dimensional Sonic Anemometer
TABLE 7-1. CSAT3B Settings and Status Values in
Device Configuration Utility
Subscreen
Setting or Status
Value
Options
Description
Unprompted
Output Rate
10 Hz
1
20 Hz
50 Hz
100 Hz
Identifies the rate at which to output
unprompted data
Measurement
Settings
Operating Mode
Mode 1
: Datalogger-
triggered | No filter |
Datalogger-prompted
output
1
Mode 2
: Self-
triggered | Filtered |
Datalogger-prompted
output
Mode 3
: Self-
triggered | No filter |
Unprompted output to
PC
Mode 4
: Self-
triggered | Filtered |
Unprompted output to
PC
Identifies the source of the measurement
trigger, whether a low pass filter will be
applied, and the output mode (see section
8.2 for more details on operating mode)
Filter Bandwidth
5 Hz
10 Hz
20 Hz
25 Hz
The cut-off frequency of the low pass filter
Instrument ID
Anemometer
Serial Number
Serial Number
1
The serial number of the CSAT3B
User ID String
Blank
1
A unique identifier in addition to the serial
number that the user may assign
Factory ID String Blank
1
A unique identifier in addition to the serial
number that the factory may assign
OS Version
-
The version number of the CSAT3B
operating system
OS Date
-
The date the loaded operating system was
built
1
Denotes a factory default setting
Factory defaults for all setting may be restored by clicking the
Factory Defaults
button at the bottom of the screen in the
Device
Configuration Utility
.
The SDM communications port is always enabled.
NOTE
NOTE
24