INSTRUCTION

 MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRS451/CRS456 Submersible 

Water-Level Recording Sensor 

Revision: 1/14 

C o p y r i g h t   ©   2 0 1 3 - 2 0 1 4  

C a m p b e l l   S c i e n t i f i c ,   I n c .  

Содержание CRS451

Страница 1: ...INSTRUCTION MANUAL CRS451 CRS456 Submersible Water Level Recording Sensor Revision 1 14 C o p y r i g h t 2 0 1 3 2 0 1 4 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...emoving reinstalling and shipping defective products to Campbell Campbell will return such products by surface carrier prepaid within the continental United States of America To all other locations Ca...

Страница 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Страница 5: ...ing Freezing Conditions 5 6 3 Dislodge Bubbles 5 6 4 Well Installation 5 6 5 Other Installations 6 6 6 Battery Voltage Reading 6 6 7 Attaching Suspension Cable to CRS451 CRS456 6 7 Programming 8 7 1 S...

Страница 6: ...Table of Contents Appendices A Calibration Certificate A 1 B Conversion to Units of Measurement B 1 Table B 1 Conversion Factors B 1 ii...

Страница 7: ...environments Before using the CRS451 CRS456 please study Section 2 Cautionary Statements Section 3 Initial Inspection Section 6 Installation 2 Cautionary Statements The CRS451 CRS456 will be damaged...

Страница 8: ...cycle can be as fast as 1 second The design features a piezoresistive sensor housed in a 316L stainless steel CRS451 or titanium CRS456 package to enhance reliability The rugged construction makes the...

Страница 9: ...Battery Life 5 years when logging interval is once per hour Power Consumption Quiescent Current 80 A Measurement CommunicationCurrent 4 mA for 1 s measurement Measurement Ranges1 Pressure psig Pressu...

Страница 10: ...ssure If a barometric pressure sensor is used to remove the component of atmospheric pressure from the pressure reading provided by the CRS451 CRS456 while submerged in a column of water vented to the...

Страница 11: ...reezing water 6 3 Dislodge Bubbles While submersing the CSR451 CRS456 air bubbles may become trapped inside the nose cone causing small offset errors until the bubbles dissolve Dislodge these bubbles...

Страница 12: ...ife difficult by measuring battery voltage alone Knowing the energy consumption of the CRS451 CRS456 while in operation HydroSci displays a predicted remaining battery life by combining an estimate of...

Страница 13: ...CRS451 CRS456 Submersible Water Level Recording Sensor 7...

Страница 14: ...S451 CRS456 If you are using an XP computer please have the driver disc in the CD DVD drive before plugging in the USB cord A driver will need to be installed before the computer can connect with the...

Страница 15: ...measurements you want to make a Barometer Pressure Reference should be selected if you want to use CR45X sensor as a barometer to compensate for changes in barometric pressure See Section 7 4 2 Using...

Страница 16: ...e the Start Time otherwise the offset correction will not be correct 5 Select a Start and Stop Time a Select a time in the future when measurements should begin Selecting a time in the past will force...

Страница 17: ...l Recording Sensor b If desired select time in future when measurements should cease c Select the rate at which measurements will be made This does not configure the senor for data storage only the ra...

Страница 18: ...or 6 Select and Name Data Tables for Datalogging a Up to four different Data Tables can archive data at independent intervals with any combination of elements samples averages maximum etc b Contents o...

Страница 19: ...CRS451 CRS456 Submersible Water Level Recording Sensor 7 Select which data in which format and unit of measurement is to be included in each of the data tables selected in the previous screen 13...

Страница 20: ...ting If the Start Time is in the past the CRS45X will immediately begin logging data but any offset you may have applied will not be effective Also if the Stop Time is in the past no data will be logg...

Страница 21: ...Field Application window choose Barometer Pressure Reference see Section 7 3 Configure CRS45X for Measurements 7 4 2 Using a Barometer The barometric pressure data from a nearby Campbell Scientific w...

Страница 22: ...ometric pressure values a The Field Application Used to Produce Collected Measurement Data information will be shown based on the collected data file selected 3 Press the browse button next to the Bar...

Страница 23: ...t of pressure or level If from a nearby Campbell Scientific weather station note that the reference column must have units associated with it The units can be any pressure or level units as defined in...

Страница 24: ...corrected data file should be stored Rename the file as applicable 6 After completing all of the fields press the Build Corrected Data File button 7 Once the corrected data file has been built press t...

Страница 25: ...lick The selection will be highlighted and will automatically be added to the graph Multiple columns can be added by holding the Ctrl key and dragging the mouse pointer over the column headings To see...

Страница 26: ...umber and fill out the Declaration of Hazardous Material and Decontamination form 8 1 Every Visit Collect data Visually inspect the physical conditions Check battery condition by using a laptop and Hy...

Страница 27: ...CRS451 CRS456 Submersible Water Level Recording Sensor 8 3 Battery Replacement Remove the set screws on the cap end of the CRS451 New Battery Screwdriver 21...

Страница 28: ...CRS451 CRS456 Submersible Water Level Recording Sensor Gently pull the end out of the housing Unplug the connecter 22...

Страница 29: ...CRS451 CRS456 Submersible Water Level Recording Sensor Gently pull the battery out the end Disconnect the battery Remove the battery Slide in the new battery Plug in the new battery 23...

Страница 30: ...CRS451 CRS456 Submersible Water Level Recording Sensor Slide the battery into the housing Reconnect the cable 24...

Страница 31: ...ible Water Level Recording Sensor Gently slide the end piece with its O rings into the housing Nicking the O ring could result in a leak Line up the holes and insert the set screw Do not over tighten...

Страница 32: ...er data include Low battery Damaged CRS451 CRS456 Water damage Damage to diaphragm due to excessive pressure Atmospheric pressure not subtracted from pressure reading Problem Unit will not respond whe...

Страница 33: ...e test chamber at the time of testing Pressure After kPa represents the resulting measurement output by the CRS451 CRS456 at the given pressure and temperature Finally Deviation After F S provides the...

Страница 34: ...Appendix A Calibration Certificate A 2...

Страница 35: ...ppendix B Conversion to Units of Measurement TABLE B 1 Conversion Factors Unit of Measurement Factor of Conversion Feet 2 3066587369 Inches 27 679904843 Meters 0 1019716213 Millimeters 101 9716213 B 1...

Страница 36: ...Appendix B Conversion to Units of Measurement B 2...

Страница 37: ......

Страница 38: ...ANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbell...

Отзывы: