![Campbell CR800 Series Скачать руководство пользователя страница 514](http://html1.mh-extra.com/html/campbell/cr800-series/cr800-series_operators-manual_489099514.webp)
Section 11. Glossary
514
principle behind thermocouple temperature measurement. It also causes
small, correctable voltage offsets in CR800 measurement circuitry.
Term: sequential mode
A CRBasic program execution mode wherein each statement is evaluated in
the order it is listed in the program. More information is available in section
Sequential Mode
(p. 152).
See
pipeline mode
(p. 509).
Term: semaphore (measurement semaphore)
In sequential mode, when the main scan executes, it locks the resources
associated with measurements. In other words, it acquires the measurement
semaphore. This is at the scan level, so all subscans within the scan
(whether they make measurements or not), will lock out measurements from
slow sequences (including the auto self-calibration). Locking measurement
resources at the scan level gives non-interrupted measurement execution of
the main scan.
Term: send
Send
button in
datalogger support software
(p. 86).
Sends a CRBasic program
or operating system to a CR800.
Term: serial
A loose term denoting output of a series of ASCII, HEX, or binary characters
or numbers in electronic form.
Term: Settings Editor
An editor for observing and adjusting CR800 settings.
Settings Editor
is a
feature of
LoggerNet
|
Connect
,
PakBusGraph
, and
Device Configuration
Utility
(
DevConfig
).
Term: Short Cut software
A CRBasic program wizard suitable for many CR800 applications.
Knowledge of CRBasic is not required to use
Short Cut
. It is available at no
charge at
www.campbellsci.com
.
Term: SI (Système Internationale)
The uniform
i
nternational
s
ystem of metric units. Specifies accepted units of
measure.
Содержание CR800 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 34: ......
Страница 54: ......
Страница 92: ......
Страница 190: ...Section 7 Installation 190 FIGURE 40 Running Average Frequency Response FIGURE 41 Running Average Signal Attenuation ...
Страница 310: ......
Страница 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Страница 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Страница 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Страница 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Страница 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Страница 456: ......
Страница 462: ......
Страница 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Страница 524: ......
Страница 526: ......
Страница 556: ......
Страница 558: ......
Страница 560: ......
Страница 597: ......