![Campbell CR6 Series Скачать руководство пользователя страница 212](http://html1.mh-extra.com/html/campbell/cr6-series/cr6-series_product-manual_3769841212.webp)
l
High RF Data Rate: Should be used when the transceivers are close together and data
throughput needs to be optimized. Setting 2 must also be used when the full throughput
of 115.2KBaud is necessary.
l
Normal RF Data Rate: Should be used when the transceivers are farther away and a solid
data link is preferred over data throughput.
Note: In MultiPoint networks, the RF Data Rate must be set identically in all transceivers. Any
transceiver with an RF Data Rate different from the Master will not establish a link. In Point to
Point networks the Masters settings take precedence over the Slave.
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: RF451 > RF Data Rate
10.4.74.3 RadioDiag
Provides diagnostics data to be viewed at the Master in parallel with application data. The
diagnostic program MUST be run from the Master transceiver. Diagnostics require the following:
1. RadioRepeaters set to 1 and RadioDiag set to (1 to 128) in the Master.
2. A second computer or serial connection to run the diagnostics software.
3. A diagnostics cable.
4. Diagnostics software.
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: RF451 > Diagnostics
10.4.74.4 RadioEnable
Global control for the internal radio module.
Where to find:
l
Settings Editor tab in Device Configuration Utility: RF451 > RF451 Radio Enable
10.4.74.5 RadioFirmwareVer
Radio firmware version.
l
Long data type
l
Read only
10. Information tables and settings (advanced)
194