![Campbell CR6 Series Скачать руководство пользователя страница 195](http://html1.mh-extra.com/html/campbell/cr6-series/cr6-series_product-manual_3769841195.webp)
10.4.7 CSIOInfo
Reports the IP address, network mask, and default gateway for each of the data logger's active
network interfaces. If DHCP is used for the interface, this setting will report the value that was
configured by the DHCP server.
l
String data type
10.4.8 DisableLithium
Controls whether the data logger will maintain its real time clock and battery backed memory
when it loses power. Setting this value to one will cause the data logger clock to lose time on
power loss. If this value is set to one, the data logger will not maintain its program or data after it
powers down.
This value is useful when the data logger needs to be stored as it will prolong the shelf life of the
lithium battery almost indefinitely.
If this value is set to one, the data logger will set it to zero when it powers up.
10.4.9 DeleteCardFilesOnMismatch
Controls the behavior of the data logger when it restarts with a different program and it detects
that data files created by the
CardOut()
are present but do not match the new program. If this
value is set to one, the data logger will delete these files so that new files can be stored. If set to a
value of zero, the data logger will retain the existing files and prevent any data from being
appended to these files.
10.4.10 DNS
This setting specifies the addresses of up to two domain name servers that the data logger can
use to resolve domain names to IP addresses. Note that if DHCP is used to resolve IP information,
the addresses obtained via DHCP will be appended to this list.
l
String data type
10.4.11 EthernetInfo
Reports the IP address, network mask, and default gateway for each of the data logger's active
network interfaces. If DHCP is used for the interface, this setting will report the value that was
configured by the DHCP server.
l
String data type
l
Read only
10. Information tables and settings (advanced)
177