Section 8. Operation
438
•
FTP
o
Send and change datalogger programs.
o
Send data that have been written to a file.
•
HTTP
o
Send datalogger programs.
o
View table data.
o
Get historical records or other files present on the datalogger drive
spaces.
o
More access is given when a .csipasswd is in place, so ensure that
users with administrative rights have strong log-in credentials.
8.7.2 Pass-Code Lockout
Pass-code lockouts (historically known in Campbell Scientific dataloggers simply
as "security codes") are the oldest method of securing a datalogger. Pass-code
lockouts can effectively lock out innocent tinkering and discourage wannabe
hackers on non-IP based comms links. However, any serious hacker with
physical access to the datalogger or to the comms hardware can, with only
minimal trouble, overcome the five-digit pass-codes. Systems adequately
secured with pass-code lockouts are probably limited to the following:
•
Private, non-IP radio networks
•
Direct links (hardwire RS-232, short-haul, multidrop, fiber optic)
•
Non-IP satellite
•
Land-line, non-IP based telephone, where the telephone number is not
published
•
Cellular phone wherein IP has been disabled, providing a strictly serial
connection
Up to three levels of lockout can be set. Valid pass codes are 1 through 65535 (0
confers no security).
Note Although a pass code can be set to a negative value, a positive
code must be entered to unlock the CR3000. That positive code will
equal 65536 + (negative security code). For example, a security code of -
1111 must be entered as 64425 to unlock the CR3000.
Содержание CR3000 Micrologger
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 30: ......
Страница 34: ......
Страница 36: ......
Страница 96: ......
Страница 200: ...Section 7 Installation 200 FIGURE 42 Running Average Frequency Response FIGURE 43 Running Average Signal Attenuation ...
Страница 485: ...Section 8 Operation 485 8 11 2 Data Display FIGURE 110 Keyboard and Display Displaying Data ...
Страница 487: ...Section 8 Operation 487 FIGURE 112 CR1000KD Real Time Custom ...
Страница 488: ...Section 8 Operation 488 8 11 2 3 Final Storage Data FIGURE 113 Keyboard and Display Final Storage Data ...
Страница 489: ...Section 8 Operation 489 8 11 3 Run Stop Program FIGURE 114 Keyboard and Display Run Stop Program ...
Страница 491: ...Section 8 Operation 491 FIGURE 116 Keyboard and Display File Edit ...
Страница 495: ...Section 8 Operation 495 Low power standby whenever possible Low power bus sets bus and modules to low power ...
Страница 496: ......
Страница 502: ......
Страница 564: ...Section 11 Glossary 564 FIGURE 126 Relationships of Accuracy Precision and Resolution ...
Страница 566: ......
Страница 594: ......
Страница 598: ......
Страница 600: ......
Страница 602: ......
Страница 624: ......
Страница 642: ......
Страница 643: ......