Accuracy (does not include sensor or measurement noise):
l
0 to 40 °C: ±(0.04% of measu offset)
l
–40 to 70 °C: ±(0.1% of meas offset)
Voltage Measurement Accuracy Offsets:
Typical Offset (µV RMS)
Range (mV)
Differential
with Input Reversal
Differential
without Input Reversal
Single-Ended
–100 to +2500
±20
±40
±60
–34 to +34
±6
±14
±20
Measurement Settling Time: 20 µs to 600 ms; 500 µs default
Multiplexed Measurement Time:
These are not maximum speeds. Multiplexed denotes circuitry inside the data logger that
switches signals into the ADC.
Measurement time = (multiplexed measurement time + settling time) • reps +0.8 ms
Differential
with Input Reversal
Single-Ended or Differential
without Input Reversal
Example fN1
1
(Hz)
Time
2
(ms)
Time
2
(ms)
4000
2.9
1.4
400
14.6
7.3
50/60
103
51.5
1
Notch frequency (1/integration time).
2
Default settling time of 500 µs used.
See also
19.5.2 Resistance measurement specifications
The data logger makes ratiometric-resistance measurements for four- and six-wire full-bridge
circuits and two-, three-, and four-wire half-bridge circuits using voltage excitation. Typically, at
least one terminal is configured for excitation output. Multiple sensors may be able to use a
common excitation terminal.