![Campbell CR1000X Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/campbell/cr1000x/cr1000x_product-manual_489087059.webp)
l
Dim/flashing orange: Card has been removed and has been out long enough that CPU
memory has wrapped and data is being overwritten without being stored to the card.
5.6 File management via powerup.ini
Another way to upload a program, install a datalogger OS, or format a drive is to create a
powerup.ini file. The file is created with a text editor and saved to a memory card or SC115 with
the associated files. Alternatively, the powerup.ini file and associated files can be saved to the
datalogger using the datalogger support software File Control > Send command. With the
memory card or SC115 connected, or with the powerup.ini file saved in the datalogger memory, a
power cycle to the datalogger begins the process chosen in the powerup.ini file.
When uploading a program, the following rules determine what datalogger program to run:
l
If the Run Now program is changed, then it is the program that runs.
l
If no change is made to the Run Now program, but the Run on Power Up program is
changed, the new Run on Power Up program runs.
l
If neither Run on Power Up nor Run Now programs are changed, the previous Run on
Power Up program runs.
Syntax for the powerup.ini file and available options follow.
5.6.1 Syntax
Syntax for powerup.ini is:
Command,File,Device
where,
l
Command
is one of the numeric commands in the following table.
l
File
is the accompanying operating system or user program file.
l
Device
is the datalogger memory drive to which the accompanying operating system or
user program file is copied (usually CPU). If left blank or with an invalid option, default
device will be CPU. Use the same drive designation as the transporting external device if
the preference is to not copy the file.
WARNING:
Uploading a program, installing a datalogger OS, or formatting a drive may result in data
loss. Depending on several factors, the datalogger may also become incapacitated for a time.
It is recommended that you retrieve data from the datalogger and back up your programs
before sending a powerup.ini file; otherwise, data may be lost. To collect data using
LoggerNet, connect to your datalogger and click Collect Now (
). To backup your
5. Data memory
43
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...