3.1.2
USB
or
RS-232
communications
Setting
up
a
USB
or
RS-232
connection
is
a
good
way
to
begin
communicating
with
your
data
logger.
Because
these
connections
do
not
require
configuration
(like
an
IP address),
you
need
only
set
up
the
communications
between
your
computer
and
the
data
logger.
Use
the
following
instructions
or
watch
the
Quickstart
videos
at
.
Initial
setup
instruction
follows.
These
settings
can
be
revisited
using
the
data
logger
support
software
Edit
Datalogger
Setup
option
.
1. Using data logger support software, launch the EZSetup Wizard.
l
PC200W and PC400 users, click Add Datalogger
.
l
LoggerNet users, click Setup
, click the View menu to ensure you are in the EZ
(Simplified) view, then click Add Datalogger.
2. Click Next.
3. Select your data logger from the list, type a name for your data logger (for example, a site
or project name), and click Next.
4. If prompted, select the Direct Connect connection type and click Next.
5. If this is the first time connecting this computer to a CR1000X via USB, click Install
USB Driver, select your data logger, click Install, and follow the prompts to install the
USB drivers.
6. Plug the data logger into your computer using a USB or RS-232 cable. The USB connection
supplies 5 V power as well as a communications link, which is adequate for setup, but a 12V
battery will be needed for field deployment. If using RS-232, external power must be
provided to the data logger and a CPI/RS-232 RJ45 to DB9 cable is required to connect to
the computer.
NOTE:
The Power LED on the data logger indicates the program and power state. Because the
data logger ships with a program set to run on power-up, the Power LED flashes 3 times
every 10 seconds when powered over USB. When powered with a 12 V battery, it flashes
1 time every 10 seconds.
7. From the COM Port list, select the COM port used for your data logger.
8. USB and RS-232 connections do not typically require a COM Port Communication Delay -
this allows time for the hardware devices to "wake up" and negotiate a communications
link. Accept the default value of 00 seconds and click Next.
9. The baud rate and PakBus address must match the hardware settings for your data logger.
The default PakBus address is 1. A USB connection does not require a baud rate selection.
RS-232 connections default to 115200 baud.
3. Setting up the data logger
17
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...