Keyword
Information and Location
EthernetPower
This setting specifies how the datalogger controls power to its Ethernet
interface. This setting provides a means of reducing the datalogger
power consumption while Ethernet is not connected. Always on, 1
Minute, or Disable.
Where to find:
l
Settings Editor tab in Device Configuration Utility: Ethernet |
Ethernet Power
FilesManager
This setting controls how the datalogger will handle incoming files with
specific extensions from various sources. There can be up to four
specifications. Each specification has three required fields: PakBus
Address, File Name, and Count.
l
String data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Advanced |
Files Manager
FTPEnabled
Set to 1 if to enable FTP service. Default is 0.
l
Numeric data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Network
Services | FTP Enabled
FTPPassword
Specifies the password that is used to log in to the FTP server.
l
String data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Network
Services | FTP Password
9. Tips and troubleshooting
143
Содержание CR1000X
Страница 1: ...Revision 02 21 2019 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...Appendix A Glossary 176 Appendix B Index 214 Table of Contents viii ...
Страница 20: ...l Smart sensors o SDI 12 o RS 232 o Modbus o DNP3 o TCP IP o RS 485 1 Data acquisition system components 4 ...
Страница 192: ......
Страница 237: ...wiring panel 5 Appendix B Index 220 ...