Appendix C. Wiring the CR6 and Optional Energy Balance Sensors
C-9
TABLE C-11. Default Wiring for Soil Heat Flux Plates (Self Calibrating).
Sensor
Quantity
Wire Description
Color
CDM-A116 Terminal
HFP01SC #1
1
Signal
White
CDM Diff 9H
Signal Reference
Green
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Signal
Yellow
CDM Diff 11H
Heater Reference
Purple
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Power
Red
CDM SW12-1
1/
Power Reference
Black
CDM G
HFP01SC #2
1
Signal
White
CDM Diff 9L
Signal Reference
Green
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Signal
Yellow
CDM Diff 11L
Heater Reference
Purple
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Power
Red
CDM SW12-1
1/
Power Reference
Black
CDM G
HFP01SC #3
1
Signal
White
CDM Diff 10H
Signal Reference
Green
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Signal
Yellow
CDM Diff 12H
Heater Reference
Purple
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Power
Red
CDM SW12-2
1/
Power Reference
Black
CDM G
HFP01SC #4
1
Signal
White
CDM Diff 10L
Signal Reference
Green
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Signal
Yellow
CDM Diff 12L
Heater Reference
Purple
CDM AG
⏚
Shield
Clear
CDM AG
⏚
Heater Power
Red
CDM SW12-2
1/
Power Reference
Black
CDM G
1/
The SW12 ports on the CDM-A116 are limited to 200mA output. Accordingly, no more than two HFP01SC sensors may
be connected to each port. Connect heater power wires from HFP01SC #1 and #2 to SW12-1, and connect heater wires from
HFP01SC #3 and #4 to SW12-2.
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...
Страница 55: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 46 ...