COM320 Voice Communications Modem
14
The
VoiceSetup()
UseTimeout
parameter determines whether or not the
datalogger will hang up the COM320 after the timeout in the
VoiceKey()
instruction expires.
5.2.4 VoiceNumber
The
VoiceNumber()
instruction returns the accumulated touch tone digits that
are received prior to the receipt of a # or * key. The example voice
callback/callin program uses no VoiceNumber instructions; however, this
instruction may be useful for phone transfer of long numbers such as for
passwords, etc.
5.2.5 DialVoice
The
DialVoice()
instruction is used to define the dialing string for a COM320
voice modem, usually for voice callback. If the
DialVoice()
instruction is set
equal to a variable, True will be returned if the communication attempt was
successful or False will be returned if it failed.
VoiceHangup
is used after a
communication attempt to hang up the voice modem. The DialString is the
telephone number and any other codes used to dial the modem. The DialString
can be a variable. A comma in the DialString inserts a 2 second pause.
5.2.6 VoiceHangup
The
VoiceHangup
instruction is used most often with the
DialVoice()
instruction to hang up the modem after communication. The
VoiceHangup
instruction is not needed if the voice commands are enclosed within the
VoiceBeg
/
EndVoice
instructions.
5.2.7 VoiceSetup
The
VoiceSetup()
instruction controls the hang up of the COM320 voice
modem. It also allows you to specify certain handset key functions:
The
HangUpKey
parameter specifies the key that, when pressed, will
disconnect the COM320.
The
ExitSubKey
parameter specifies the key that will exit a subroutine if the
datalogger is running one. The
ContinueKey
parameter specifies the key that
will begin announcing the next VoiceSpeak phrase.
The
SecsOnLine
parameter specifies the maximum number of seconds that the
COM320 will be off-hook before it is hung up by the datalogger.
The
UseTimeout
parameter determines whether or not the datalogger will hang
up the COM320 after the timeout in the
VoiceKey()
instruction expires. If this
parameter is set to True, the timeout will be used. If False, the timeout will not
be used.
The
CallOut
parameter is a Boolean value that indicates the COM320 mode.
When the value returned in this parameter is True, the datalogger has called
out. When the value is False, the datalogger has received an incoming call.
If the same ASCII character is used for
HangUpKey
and
ExitSubKey
, the
datalogger will exit a subroutine if it is in one, otherwise, it will hang up the
COM320. When the specified
ContinueKey
is pressed, the COM320 will skip