FIGURE 6-2. Voltage input connections on the CH201
6.1.2 DC power
Double-check the input voltages coming in to the charger/regulator with a volt meter.
DC In 1 Input Voltage: 15 to 50 VDC
DC In 2 Input Voltage: 15 to 50 VDC
WARNING:
Exceeding the maximum voltage will damage the CH201. Only one input is used at a time,
whichever has a higher voltage.
6.2
Connect
to
battery
Only
use
the
following
battery
cables
with
the
CH201:
pn
#
34029,
pn
#
34031,
pn
#
34040,
and
pn
#
36589.
Connect
the
red
wire
to
the
positive
battery
post
and
the
black
wire
to
the
negative
battery
post.
Inset
the
connector
into
the
CH201
BAT
port.
6.3
Connect
to
data
logger
The
CH201
comes
with
a
1-foot
black
wire
attached
to
a
G
terminal
block
and
a
1-foot
red
wire
attached
to
a
12V
terminal
block.
The
data
logger
includes
a
voltage
input
terminal
connector.
The
wires
from
the
CH201
attach
to
this
connector,
which
plugs
into
the
Power In
terminal
on
the
data
logger.
Attach
the
red
wire
from
the
CH201
to
the
12V
terminal
on
the
connector;
attach
the
black
wire
to
the
G
terminal,
then
plug
the
connector
into
the
data
logger.
CH201 12V Charging Regulator
11
Содержание CH201
Страница 1: ...06 2020 Copyright 2020 Campbell Scientific CSL I D 1352 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ...Appendix A Downloading an operating system 31 Table of Contents ii ...
Страница 42: ...FIGURE A 1 Downloading a new operating system CH201 12V Charging Regulator 32 ...
Страница 43: ......