User Manual
9
4.
Specifications
4.1
Specifications
(CHARGE - CHARGE terminals)
AC or DC Source:
AC – (18 to 24) VRMS internally
limited to 1.2 ARMS
DC – (16 to 40) VDC internally limited
to 0.85 Adc
(SOLAR -
terminals)
Solar Panel or Other DC Source
1
:
15 to 40 VDC
Maximum Charging Current:
4.0 Adc typical
3.2 Adc to 4.9 Adc
depending upon individual charger
Battery Charging
FLOAT Charging: Vbatt(T) =
13.65 – (24 mV)•(T – 25) +
(0.24 mV)•(T – 25)
2
1% Accuracy on charging voltage over
–40° to +60
C range
Operational Temperature Range
2
:
–40° to +60
C
Power Out (+12 terminals)
Voltage:
Unregulated 12 V from Battery
4.65 A solid-state circuit breaker
Quiescent Current
No Charge Source Present:
160
A at 13.7 VDC
No Battery Connected:
930
A at 30 volt input voltage (AC or
DC)
Rated UL Class 2 Power Supply
Physical Specifications
PS150:
10.6 cm (4.2 in) tall, 19.3 cm (7.5 in)
long, 7.6 cm (3 in) wide
CH150:
10.0 cm (3.9 in) tall, 7.5 cm (3 in) long,
3.7 cm (1.5 in) wide
Compliance:
View the EU Declaration of Conformity
at
1. Battery voltages below 8.7 V may result in < 3.0 A current limit because of
foldback current limit.
2. VRLA battery manufacturers state that “heat kills batteries” and recommend
operating batteries
50
C.
Содержание CH150
Страница 1: ...PS150 CH150 12 V Charging Regulators Revision 20 6 19 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ...ii ...
Страница 25: ...User Manual 15 Figure 7 2 Installing the A100 Figure 7 3 A100 mounting screw Screw ...
Страница 27: ...User Manual 17 ...